Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
15-inch, 800x600 color TFT, multi-channel display capable of showing up to 13 wave channels simultaneously.
Advanced DSP algorithm for unparalleled SpO2 performance during patient movement, coupled with PI for superior functionality even in low perfusion conditions.
NIBP VET algorithm designed to support a range of animals from small cats to horses, featuring overpressure protection for enhanced safety.
Distinctive human voice alarm for prompt notifications.
Equipped with a standard RJ45 network port; optional USB WIFI module available for seamless CMS connectivity.
USB data output accompanied by software for easy data viewing on a computer.
Gas module capable of auto-detecting 5 anesthesia gas types: HAL, ENF, ISO, SEV, DEV.
Versatile screen layouts including big font options; parameters and waveforms can be individually toggled for each accessory cabinet.
Technical Specifications
ECG | SPO2 |
Lead : 3/5 | SpO2,PR,PI |
5 lead mode: I, II, III, aVR, aVL, aVF, V | Accuracy: ±2%( 70~100%) |
3 ECG channels, 7 ECG waves in ECG full lead mode | Pulse Rate: 20~250bpm |
HR:15-500BPM | Temperature |
Gain : X1/4,X1/2,X1,X2 | Channel : 2 |
Wave speed : 12.5/25/50 mm/s | Measure and Alarm Range0 - 50°C |
Pacemaker | Sensor type : rectal |
Arrythmia analysis | Unit : °C |
ST analysis | Accuracy : ±0.1°C |
Filter mode: other, monitor, surgery | Recorder |
RESP | 3 channals |
Impedance between RA-LL or RA-LA | Storage |
RESP lead : I/II | ≥720 hours trend graph and trend table |
Wave speed : 6.25, 12.5, 25mm/s | 2 houss wave review |
Apnea Alarm,5~120s | 200 alarm review |
NIBP | Alarm |
Method : Oscillometry | 3 levels alarm |
For animal from <10kg to > 20kg | All the alarm limit can be adjusted by user. |
Unit : mmHg ,Kpa | Unique Voice alarm |
Mode: Manual,Auto,STAT | IBP |
Measure and Alarm Range | Sensor: OHMEDA or BD, EDWARD compatible |
SYS 40~280 mmHg | Channels: 2 |
DIA 10 ~220 mmHg | Measuer Range: -50~ 360 (mmHg) |
MEAN 20 ~ 240 mmHg | Accuracy(no sensor): ±2% or £1mmHg, use the greater |
Cuff 0 ~ 300mmHg | CO2 |
Static pressure: ±3mmHg | Measuer Range: 0%~13% |
Automatic measurement interval time: | Accuracy: ±2 mmHg @<5.0% COz (at ATPS) |
1 minute ~ 480 minutes | Breath Rate: 3- 150 bpm |
Standard:
ECG, NIBP, SpO2, PR, TEMP, RESP
Optional:
Mainstream/Sidestream EtCO2,
GAS, IBP-1/IBP-2, Thermal Recorder,
Wall Mount, Trolley, CMS