• Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator
  • Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator
  • Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator
  • Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator
  • Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator
  • Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator

Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator

Classification: Biological Diagnostics
Type: SpO2 Simulator
Certification: CE
Group: All People
Voltage: DC 3.6V~4.2V
Power Supply: Voltage 3.7 Rechargeable Lithium Battery
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
MCS0396
Battery Working Life
Charge and Discharge No Less Than 500 Times.
Transport Package
Carton
Specification
189mm(L)*125mm(W)*56 mm(H)
Trademark
MeCan
Origin
China
Production Capacity
500pieces/Year

Product Description

Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator

Model:MCS0396
Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator

Product Description

Specifications
Several widely used R-curves pre-enbeded, 24 conditions presetting and 8 conditions as default after start.

Brief Introduction
It is a separated SpO2 simulator which features in small volume and light weight. As different manufacturers may use different R-curve, parts of current popular R-curve are embedded into the simulator in advance.

Features:
1.Separated design for simulator probe and host, convenient to test and operate.
2.Simulate SpO2 and PR under different ampli
-tudes.
3.SpO2 simulation.
4.Pulse rate simulation.
5.Simulate presettable patient state.
6.Test reaction time of the device.
7.TFT-LCD with adjustable backlight brightness.
8.Film button, more comfortable to operate.
9.With rechargeable lithium battery.
10.Test device performance under different interfer
-ence source.


Main Functions
Oxygen saturation simulation;
Pulse rate simulation;
Patient state simulation preset;
Can test the reaction time of device;
Can simulate the SpO2 and pulse rate under different amplitude;
Can test the performance of device under different interference source;
Can select different R-curve.

 

Main Parameters
SpO2 1.Measuring range: 35%~100%
2.Resolution:1%
3.Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
Pulse rate 1.Measuring range: 25bpm~250bpm
2.Resolution: 5bpm
3.Error: 1%± 1bpm
Amplitude 1.Measuring range:0.000%~20.000% 
2.Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
Patient state 24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.


Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator

Company Profile

Pulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation SimulatorPulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation SimulatorPulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation SimulatorPulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation SimulatorPulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation SimulatorPulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation SimulatorPulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation SimulatorPulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation SimulatorPulse Oximeter SpO2 Pulse Rate Simulator Oxygen Saturation Simulator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now