ESR Fast Detector Tube Spirit Level

Product Name: ESR Fast Detector Tube Spirit Level
Brand Name: Mecan
Type: Blood Testing Equipments
Size: 9*120mm
Transport Package: Standard Export Package
Trademark: MeCan
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
MCL-828
Origin
China (Mainland)
Production Capacity
1000

Product Description

ESR Fast Detector tube spirit level

MCL-828

Product Description

Main Features:
Better compatibility compared with Westergren method.
A safe, reliable and airtight operation during the whole process from blood collection to test, free of biological contamination.
Designed with spirit level of patent technology, which ensures the detector horizontal and aclinic.
10 channels, synchronous operation allowed.
Only 30 minutes needed for reading, easy and fast.
Stainless steel soleplate with silicagel cushion on, which will avoid any noise or breakage when the ESR tube being placed.

How to use:
Carry out the venous blood collection according to standard requirements with 9*120mm ESR vacuum tube.
Immediately invert the tube at 180 degrees for 6-8 times to achieve through mixing, which will avoid hemolysis, clotting or blood bubble.
At the room temperature of around 20ºC, vertically place the ESR tube cotaining blood sample onto the detector, note down the starting time and relevent numbers. Keep the detector still for 30minutes and then read the millimeter of erythrocyte sedimentation.
Detailed reading method: Keep it stable for 30min, align the plasma concave in ESR tubes to zero scare of the detector. Then, read the data by aligning the upper surface of erythrocyte to the scale on the detector.(See as the schematic diagram)

Notice:
Before operation, the ESR fast detector should be put on a steady platform and adjusted to be horizontal with knobs below the soleplate.
The ESR tubes should be kept vertical during the whole sedimentation process, angle of inclination should not be more than 3°. Orelse, the testing result will be of large deviation.
Keep the room temperature at 20±5ºC, sedimentation time 30±2min.ESR Fast Detector Tube Spirit Level
ESR Fast Detector Tube Spirit Level
ESR Fast Detector Tube Spirit Level

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2015

Suppliers with verified business licenses

Trading Company
Year of Establishment
2011-12-26
Management System Certification
ISO 9001, ISO 9000, ISO 13485