Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Hospital Baby Incubator Tilt adjustable infant Incubator
Model:MCG8001
Brief Introduction
* Two control modes: Air mode and Baby mode controlled by micro-computer;
* Set temperature, Air temperature, Baby temperature are displayed separately;
* Humidity control system;
* Inclination of bassinet is adjustable;
* Multiple failure alarm indications;
* RS-232 connector for data output;
* Oxygen input interface;
* The pressure difference between the spiral duct and the tributary centrifugal fan ensures that fresh air is always inhaled;
* Configured with fixed Neonate Bilirubin Phototherapy Equipment model with blue fluorescent lamp as the upper light source; or fixed Neonate Bilirubin Phototherapy Equipment model with blue LED is optional;
* Configured with fixed Neonate Bilirubin Phototherapy Equipment with SMD blue LED under the bassinet as the nether light source;
* Low noise DC motor.
Standard Configuration
Main body, mobile cabinet, temperature controller, hood, I.V. Pole with shelf, skin temperature sensor, mattress, fixed Neonate Bilirubin Phototherapy Equipment model with blue fluorescent lamp as the upper light source, fixed Neonate Bilirubin
Optional Configuration
">37ºC" temperature override mode function, vertical height adjustment stand(VHA stand), weighing system, Neonate Bilirubin Phototherapy Equipment model with blue LED as upper light source and disposable skin temperature sensor, SpO2.
What is the specification of our baby incubator?
Power requirement | AC220V-230V/50Hz or AC110-120V, 50/60Hz, 1000VA |
Control Mode | Air mode and Baby mode controlled by micro-computer |
Control range of air temperature | 25ºC-37ºC (override mode: 37ºC-39ºC is optional) |
Control range of baby temperature | 34ºC-37ºC (override mode: 37ºC-38ºC is optional) |
Accuracy of skin temperature sensor | ±0.2ºC |
Variability of temperature | ≤0.5ºC |
Uniformity of temperature | ≤0.8ºC(mattress is on the horizontal position) |
Humidity display range | 0%RH~99%RH |
Humidity control range | 20%~90%RH |
Inclination of the bassinet | ±12° |
Noise inside hood | ≤45dB(A) (Environment noise ≤35dB(A)) |
Failure alarm | Over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on. |
The average value of total irradiance for bilirubin Ebi max of phototherapy equipment | ≥10uW/cm2/nm (blue fluorescent lamp) ≥21uW/cm2/nm (blue LED) |
The average value of total irradiance for bilirubin Ebi max of phototherapy equipment under bassinet | ≥13uW/cm2/nm (with SMD LED) |
Built-in timer range | 0~99999.9 hrs |
Accuracy of weight display | ±1% (equipped with weighing system) |