• Mc-Ot-3008b-1 Multi-Purpose Operating Table, Head Controlled
  • Mc-Ot-3008b-1 Multi-Purpose Operating Table, Head Controlled
  • Mc-Ot-3008b-1 Multi-Purpose Operating Table, Head Controlled
  • Mc-Ot-3008b-1 Multi-Purpose Operating Table, Head Controlled

Mc-Ot-3008b-1 Multi-Purpose Operating Table, Head Controlled

Certification: ISO13485
Product Name: Surgical Operation Table
Application: Surgical Procedures and Operations
Anaesthetic Screen: 1PC
Shoulder Rest: 2PCS
Arm Rest: 2PCS
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
MC-OT-3008B-1
Body Support, Large
1PC
Body Support, Small
1PC
Knee Crutch
2PCS
Cushion
1PC
Body Restraint Strap
1PC
Transport Package
Export Standard Packaging for Air and Sea
Trademark
Mecan
Origin
China (Mainland) Guangdong
Production Capacity
5000

Product Description

Multi-Purpose Operating Table, Head controlled

Model:MC-OT-3008B-1
Mc-Ot-3008b-1 Multi-Purpose Operating Table, Head Controlled

 

What is the detail of our gynecological operating table?

1. Main Usage & Structure:
This table are compactly designed and sturdily constructed, and may be raised or lowered hydraulically by means of an oil pump. They are suitable for surgical procedures of the head, neck, thorax, abdomen, perineum and extremities as well as for gynaecological, obstetrical, urological and oto-rhino-laryngological operations. Various positions can be quickly and safely adjusted.
The controlling devices, hand wheels and crank handles are mounted at the head-end of the table. All positions of the table are controlled entirely from the head-end. Chassis inside & outside cover are stainless steel. 


2. Specifications:
Dimensions of Table Top: 
Overall length.................................2040(mm)
Width.......................................480(mm)
Dimensions of Sections:
Head Rest.................................…280×320(mm)
Back section.................................500×480(mm)
Kidney Bridge..............................…84×470(mm) 
Seat Section.................................370×480(mm)
Leg Section.................................510×480(mm)
Foot Rest.................................…200×260(mm)
Table Top from Floor :
Min. Height .................................800(mm)
Adjust....................................…≥200(mm)
Range of Movements:
Max. Reversed Trendelenburg .....................≥50°
Max. Trendelenburg...........................…≥30°
Max. Lateral Tilt..............................…≥20°
Adjustments of Sections : 
Head Rest-raised from the horizontal..................≥30°
Head Rest-lowered from the horizontal ...............…≥90°
Back Section-raised from the horizontal...............…≥80°
Back Section-lowered from the horizontal...............…≥8°
Kidney Bridge Elevation...........................…80mm
Leg Section-lowered from the horizontal..................≥90°
Leg Section-opened..............................…≥50°
Foot Rest-can be kept horizontally or perpendicularly to the Leg Section.
Safe working load.................................…250kg

 

3. Controlling Devices of Head-End Controlled Table:
1,Trendelenburg position, reversed Trendelenburg position and tilt in left or right direction are regulated by one single Hand wheel (2). The movements of the back section and leg section are controlled by Hand Wheel (3). For directions for use please see the label attached to the crank sleeve.
2,The kidney bridge is controlled by Crank Handle (1) situated at the center.
3,Both the ascending and descending movements of the table top are controlled by the oil pump. When the products leave the factory, the oil pump has been pumped into the pail, so the oil pump can not ascend. The Consumers must move the cover of the filling aperture at the fop of the oil pump. Use a funnel to refill the oil pump slowly. By pressing down Pedal (4) repeatedly, the table top, will begin to descend slowly and gently. Attention: Please infuse all the oil of barrel. Otherwise, the phenomenon that the tabletop can't be reached the maximum height may happen. 
4,The moving and stabilization of the base. By loosening Handle (5) of the base clockwise, the table can move. On the contrary, it can be stabilized. Attention : Do not loosen or tighten a handle, otherwise, the phenomenon that the base is not stable may happen.
Mc-Ot-3008b-1 Multi-Purpose Operating Table, Head Controlled
 

5. Cleaning, disinfection and sterilization
1,Washing the operating table with water is prohibited.
2,Clean operating table with a soft cloth, sponge, wet cloth or detergent. Not use a hard brush, steel wire brush, decontamination powder, paint, ether, bananas water, acid-base solution to any surface.
3,Mattress must be disinfection with alcohol, ether, ultraviolet disinfection and so on (abandoning high-temperature disinfection).

 

6. Environmental condition
Transportation and stockpile environmental conditions:
a)Environmental temperature:-40ºC~+55ºC.
b)Relative humidity:≤80%.
c)Atmospheric pressure:50kPa~106kPa.
Moving environmental conditions:
a)Environmental temperature:5ºC~40ºC.
b)Relative humidity:≤70%.
c)Atmospheric pressure: 70.0kPa~106.0kPa.

 

7. Cautions:
1,The Head-rest adjustment is adopted by a strict tecth lock. If the position of the head-rest needs adjusting, the tecth lock pole must be first separated and adjusted to suitable position, the got loose, otherwise it is easily damaged.
2,Lubricating oil should be added to every active part, so that the bed can be operated easily and prolong their life. Smear Vaseline over the tracks of the accessories on each side of the bed and the racks under the table, thus preventing it from being rusty.
3,Before putting into use, all attachments should be checked to see if they are locked securely so as to prevent them from loosing or sliding off while used.
4,As the bed has many parts, keep all the accessories in good order.
5,After operating every time, clean the dirt on the bed, keep the bed and accessories clean and prolong their life.
6,The ground must be kept dry. While the floor is washed and scrubed, please try not to make water spill into the plate or on the rotated wheels, thus preventing it from being rusty.
7,It must be repaired and kept clean regularly once a year.
8,The kidney bridge should be kept on the lowest position, before assemble of the folding back to protect the waist panel.
9,In the clinical use, the lateral lean angle of the operating table is bigger than 8 degrees (the standard is equal or bigger than 20 degrees), the user shoud think the possibility that the patient falls from the table top, and selects a body frame and body belt and so on to ensure the use safety.
10,The service life for operating table is nine years. If it is used in expired period, it maybe led to wearing and corrosion of some mechanical parts, and had a negative influence upon the mechanical intensity. The patients maybe suffered. So the operating table should be used in the regular maintenance and during safety using period.
11,The replacement parts during operating table normal using period, has been confirmed scrapped (unable to use), should be handled according to the classification (recyclable and non-recovery).
12,The safe working load of operating table is 135kg.

This device in package should be stored indoor with a relative humidity less than 80%, no erosive air and good ventilation is required. No side-sloping. 
It can be shipped in regular transportation without crash, oscillation, rain or direct sunlight.
Mc-Ot-3008b-1 Multi-Purpose Operating Table, Head Controlled

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now