MCU-Kd12 Full Digital Color Doppler Ultrasound Scanner

Product Details
Customization: Available
Ultrasound Scanner: 10.4′flicker-Free High-Resolution Medical Color Le
Power: 100-240V, 1.2-0.6A

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2011-12-26
Management System Certification
ISO 9001, ISO 9000, ISO 13485
  • MCU-Kd12 Full Digital Color Doppler Ultrasound Scanner
  • MCU-Kd12 Full Digital Color Doppler Ultrasound Scanner
  • MCU-Kd12 Full Digital Color Doppler Ultrasound Scanner
  • MCU-Kd12 Full Digital Color Doppler Ultrasound Scanner
Find Similar Products

Basic Info.

Model NO.
MCU-KD12
Adapter Output
DC12.8V 3.0A
Power Consumption
≤100va
Main Unit Size
256*150*326(mm, Length*Width*Height)
Unit Net Weight
4.5kg(Accessories Not Included)
Network Printing
One-Key Invoking Report Function
Energy Saving Function
Brightness of The LED Adjustment Function
Scanning
High Frame Frequency, High Density
Transport Package
Export Standard Packaging for Air and Sea
Trademark
Mecan
Origin
China (Mainland) Guangdong
Production Capacity
5000

Product Description

Full Digital Color Doppler Ultrasound Scanner

Model: MCU-KD12
MCU-Kd12 Full Digital Color Doppler Ultrasound Scanner

 

1. Designation: MCU-KD12 Full Digital Color Doppler Ultrasound Scanner

 

2. Application: Leading image process technical and advanced and practical clinical solution method. Applicable to diagnosis of abdominal organs(trans-vaginal included), superficial organs and cardiac. With scalable design, upgrade continuously, fully meet the needs of clinical application extension.

 

3. System feature: 
3.1 Adopt A8 embedded system. High reliability to keep virus away thoroughly.
3.2 Operation system: Limux system, English/Chinese menu switch alternatively.
3.3 Full digital multi-beam formation technology, high precision delay dynamic receiving focusing, ultra-wide frequency imaging, adaptive image optimization processing technique, adaptive vessel imaging, adaptive Doppler imaging.
3.4 Ultra-wide frequency full digital beam former: Dynamic focuse
3.5 Two-dimensional grey scale imaging unit
3.6 M imaging unit
3.7 Visible and adjustable dynamic range
3.8 Two-dimensional imaging unit, grey scale ≥ 256 level, excellently detailed and comparative resolution and full-screen uniformity

 

4. Parameters:
4.1 Specification parameters: 
1. Grey scale: 256 level
2. Color scale: 256 level
3. Display: 10.4'flicker-free high-resolution medical color LED
4. Power: 100-240V, 1.2-0.6A frequency: 50-60Hz

5. Adapter output: DC12.8V 3.0A
6. Power consumption: ≤100VA
7. Main unit size: 256*150*326(mm, Length*width*height)
8. Unit net weight: 4.5Kg(Accessories not included)
4.2 Multi-media and accessory equipments
1. Video recorder
2. I-station integral work station, realize image storage, report form and cloud print
3. U flash disk (file management, software upgrade and one-key storage) and DICOM port, convenient for data management and available to removal transmission.
4. Dual-mode TV output: PAL/NTSC
4.3 Probe port: 
Two enabled probe ports, automatic identification technology, available to optional probe configuration.
4.4 Language
Menu operation, interface language: English/Chinese switch alternatively
4.5 Scanning parameter:
3.5MHz R60 multi-frequency convex probe
1. Scan angle: 60°
2. Frequency range: 2.0MHz-5.0MHz
3. Frequency conversion options: 2.0/2.5/3.5/5.0
4. Max-scan depth: ≥190mm
5. Blind area: ≤5mm
6. Resolution: Axial resolution ≤1mm, Lateral resolution ≤2mm
7. Geometrical position accuracy: Horizontal ≤5%, Portrait ≤5%
7.5MHz L40 multi-frequency linear probe
1. Frequency range: 6.0MHz-9.0MHz
2. Frequency conversion options: 6.0/6.5/7.5/9.0
3. Max-scan depth: ≥60mm
4. Blind area: ≤3mm
5. Resolution: Axial resolution ≤0.5mm, Lateral resolution ≤1mm
6. Geometrical position accuracy: Horizontal ≤5%, Portrait ≤5%
6.5MHz R11 multi-frequency trans-vaginal probe
1. Scan angle: 135°
2. Frequency range: 4.5MHz-9.0MHz
3. Frequency conversion options: 4.5/5.5/6.5/7.5
4. Max-scan depth: ≥60mm
5. Blind area: ≤4mm
6. Resolution: Axial resolution ≤1mm, Lateral resolution ≤1mm
7. Geometrical position accuracy: Horizontal ≤10%, Portrait ≤5%
4.6 Operation mode:
1. B,B/B,4B
2. M,B/M
3. CFM
4. PDI
5. PW
6. THI
4.7 System set
4.7.1 I-user-defined, superior to former aimless set, note the used set down and review and store image in one key.
4.7.2 Original set
1. Hospital name: 
2. Interface langguage: Chinese/English
3. Format set
4. Character set
5. Time,date set
6. Date format: yyyy-mm-dd,mm-dd-yyyy and dd-mm-yyyy to select
7. Screensaver duration set
8. Ket sound set
4.7.3 Formula preset
1. BPD
2. CRL
3.GS
4. FL
5. HL
6. AD
7. TTD
8.APTD
9.HC
10. AC
11. FL
12. LV
13. DBH
14. Cerebellar diameter
15. OFD
16. FW
17. BSA
4.7.4 Net Preference: Local IP address,Local Area Network Server,DICOM server set
4.7.5 Annotation Preference: Lesion,General,Abdomen,Obstetrics and Gynecology,Cardiac,
Urinary,Superficial,Orthopedic Surgery. Each one has a predefined normal name, it can be added and modified for needs to convenient users.
4.7.6 Storage Preference: BMP, PNG format
4.7.7 Password Preference.
4.7.8 Regain Original set.

 

5.Ultrasonic imaging technology
1. High precise digital multi-beam formator:
Precise ultrasonic multi-beam operation eliminate side lobe noise efficiently, promote the spatial and contrast resolution greatly, show precisely organization structure.
2. Dynamic frequency fusion imaging:
Guide near to far field transmittig and receiving frequency, integrate strong penetration and high clarity perfectly.
3. High precise delay dynamic receiving focusing.
The whole image focusing point precision delay, to show the true and exquisite organize information.

4. Ultra-wideband image technique 
Choose the best center frequency optionally according to the different groups of characteristics.

5. Adaptive color artifact removal technique
According to the current organization of the reception, automatically digital parameters optimization, prevent more perfect ultrasound images.

6. Adaptive vessel imaging
In view of the current receiving Doppler echo signal, take appropriate filtering scheme automatically, effectively suppress clutter, in order to achieve the perfect combination of resolution and sensitivity, show the better blood flow images.

7. Adaptive Doppler image technique
To enhance the weak Doppler signal, and through the complex digital processing technique enhance the spectrum signal, make the sensitivity and effect of Doppler all improve.

8. THL tissue harmonic imaging technology
At a relatively low frequency ultrasonic launch and the second harmonic signal in the received echo signal for imaging, at the same time of guarantee good penetration, enhance the resolution of tissue imaging, and maximum eliminate artifacts.

 

6. Main Function
1. System preset function
2. User defined system; I-User-defined, intelligent user defined system, subverts the previously blind settings of user-defined data, and memory the settings while user processes. Meanwhile we can achieve one-key to complete the browse and save.
3. Prove switch function
4. Mode switch function 
5. Magnification/Depth function
6. Frequency conversion function
7. Frame correlation function
8. Edge enhancement adjustment function
9. Compression curve adjustment function
10. Image post-process adjustment function
11. Focal adjustment function
12. Image up/down reverse function
13. Image freeze/unfreeze function
14. Realize adjustment of TGC, total gain and dynamic range
15. I-image image optimization imaging technique 
16. Adjustment of color frequency, PRF and wall filters function
17. Sensitivity, color persistence, color threshold, color balance, color smooth and artifact removal function
18. Adjustment of deflection, sampling volume, liner array color deflection, speed scale and the baseline function
19. Harmonic adjustment function
20. B general measurement function
21. M general measurement function
22. CFM general measurement function
23. PDI general measurement function
24. PW measurement function
25. Abdominal application measurement function
26. Obstetric application measurement function
27. Cardiac application measurement function
28. Urology department application measurement function
29. Superficial application measurement function
30. Acoustic power adjustment function
31. Puncture guide: puncture guide function ( two puncture guide line , angle and position is adjustable)
32. Lithotripsy position: enquired with lithotripsy special package, realize real-time positioning measurement.
33. Storage: large internal 16G storage capacity, permanent massive storage, without loss when power off. BWP format image ≥10,000 frames, PNG format image ≥100,000 frames.
34. Image management function
35. Play back: massive cine storage, play back. ( B mode: 380 frames, M mode around 4000 frames)
36. Body mark function
37. Annotation function
38. Input patients information function
39. Generate report automatically
40. One-key storage function; the convenient and practical one-key storage function, meet the user's shortcut.
41. One-key invoking report function
42. One-key to transfer the ultrasound image to Network printer function, realize Network printing, make up the defect of the specified printer.
43. Network printing.
44. Brightness of the LED adjustment function
45. Energy saving function
46. Chinese and English switching function

 

7.The image processing introduce
Beam processing
Digital multi-beam forming technology, real-time dynamic focusing point by point, continuous dynamic focusing, real-time dynamic class variable aperture imaging technique, real time dynamic beam trace, dynamic filtering, CNC dynamic frequency scanning.

Image preprocessing
Total gain: 0 ~ 127 dB 
TGC: 8 ties rod for adjustment
Acoustic output ( power adjustable ): 25%,50%,75%,100%
Digital channel number: 32

Image processing
Edge enhancement: 0 ~ 3 levels adjustable
Frame correlation: 0 ~ 3 levels adjustable
Image post-process (IP): 0 ~ 7 levels adjustable
Compression curve: 0 ~ 7 levels adjustable

The scanning parameters
B mode:
1. B acoustic output ( power adjustable ): 25%,50%,75%,100%
2. B gain: 0 ~ 127
3. Depth range: 32 ~ 252mm ( 35 levels ) Each probe has the corresponding depth range and series adjustment.
4. Dynamic range: 30 ~ 100 Db
5. Scanning: High frame frequency, high density
6. Frequency conversion: 4 levels
7. Harmonic: 2 levels

M mode: 
1. M acoustic output ( power adjustable ): 25%,50%,75%,100%
2. M gain: 0 ~ 127dB
3. Depth range: 32 ~ 252mm ( 35 levels ) Each probe has the corresponding depth range and series adjustment.
4. M dynamic range: 27 ~ 100 dB
5. M scanning speed: 1 ~ 8 level adjustable
6. The sampling line is visual and adjustable.
7. Two M working mode: rolling, scanning
8. Scanning: high frame frequency, high density
9. Frequency conversion: 4 levels
10. Harmonic: 2 levels

CFM color Doppler mode,PID Energy Doppler mode:
1. Acoustic output ( power adjustable ): 25%,50%,75%,100%
2. CFM gain: 0 ~ 127 Db
3. Color frequency: 2 levels adjustable
4. Maximum PRF: 7.5 kHz
5. Minimum PRF: 0.35 kHz
6. CFM wall filter: 8 steps 50 - 350 Hz
7. Sensitivity: 6 kinds
8. Color persistence: 4 steps
9. Color threshold: 6 kinds
10. Color balance: 16 steps
11. Color smooth: 3 steps
12. Artifact removal: 2 steps
13. Linear array color deflection adjustable
14. Image optimization: 12 levels

PW spectrum Doppler mode:
1. Acoustic output ( power adjustable ): 25%,50%,75%,100%
2. PW gain: 0 ~ 127dB
3. PW dynamic range: 27 ~ 100 Db
4. PW frequency: 2 levels adjustable
5. PW wall filter: 8 steps 50 - 350 Hz
6. Noise suppression: 4 levels
7. Width of the sampling volume: 0.5 - 20mm 
8. Angle correction
9. Baseline adjustment: 7 steps
10. Maximum PRF ( speed ): 7.5 kHz
11. Minimum PRF (velocity) 0.35 kHz
12. Velocity ruler: 8 step
13. Volume: adapt
14. Linear array color deflection is adjustable

 

8.Measurement/ Calculate
General measurement: with B general measurement, M general measurement, D general measurement software and various measuring report function.
B mode measurement: distance, area (Trace, Ellipse), circumference (Trace, Ellipse), area (2-Axis), angle, histogram, sectional view, stenosis (DSR, ASR), depth.
M mode measurement: depth, slope, heart rate, cycle
D mode measurement: velocity, heart rate, flow velocity, time, acceleration, throb/ resistance index, maximum differential pressure, average differential pressure, ratio, cardiac output, flow.
GYN measurement and analysis: GYN software package and GYN report.
OB measurement and analysis: up to 17 kinds OB tables etc various GA measurement and AFI measurement, with fetus growth curve, fetal biophysical profile and OB report.
BPD(Biparietal Diameter), CRL(Crown Rump Length), GS(Gestational Sac), FL(Femur Length), HL(Humerus Length), TAD(Abdominal Transverse Diameter), TTD(Thorax Transverse Diameter), APTD(Thorax Anterior-Posterior Diameter), FT(Foot Length), LV(Lumbar Vertebrae), THD(Thorax Height Diameter), TCD(Transverse Cerebellum Diameter), OFD(Occipitofrontal Diameter), HC(Head Circumference), AC(Abdominal Circumference), AFI(Amniotic Fluid Index), LMP(Last Menstrual Period), BBT(Basal Body Temperature),can calculate GA ,estimated fetal weight(EFW), estimated date of childbirth (EDC),fetus growth curve, can process FBP(fetal biophysical profile).
Urology measurement and analysis: urology measurement software package and urology report.
Superficial organs measurement and analysis: Superficial organs measurement software package and report.
Orthopedic surgery measurement and analysis: Orthopedic surgery measurement software package and report.
Cardiac measurement and analysis: cardiac measurement software package and report.
1. Measurement item under B mode, B/B mode:
1) Left ventricular function measurement, can calculate cardiac output(CO), military vector chart format(MVCF), cardiac index(CI) and stroke volume index(SI).
2) Right ventricular internal diameter (RV) measurement.
3) Main pulmonary artery internal diameter (PA) measurement.

2. Measurement item under M mode, B/M mode:
1) Left ventricular function
2) Mitral valve: The falling speed of EFLSP and AC measurement, A peak and E peak value and QMV measurement.
3) Aorta
4) Cardiac output(CO)
5) Ejection time(ET)
6) Left ventricular mass weight(LVMW)

3. Measurement item under PW mode:
1).Velocity, heart rate, time
2). Acceleration
3).throb/ resistance index
The eighth page 
4).maximum differential pressure
5).average differential pressure
6).ratio
7).cardiac output
8).flow

 

9.Measurement report
OB measurement report, GYN measurement report, cardiac measurement report, urology measurement report and other measurement report, automatically store the measurement result and generate report.

 

10. Mark
1. 131 kind body marks with probe position, can through ocular body mark detail interface rapidly to choose body mark.
2. Comment mark, can preset comment context.
3. Arrow mark

 

11. Standard configurations
Main unit:1 pc
3.5 MHz convex abdomen probe:1 pc
>6.5 MHz trans-vaginal probe 
> 7.5 MHz linear probe 
Workstation software: 1 set
Reticle:1 pc

 

12. Optional configurations
Foot switch
Trolley 
Video recorder (UP-897MD)
Ethernet switch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More