Low Temperature H2O2 Plasma Sterilization Equipment 30L100L 200L

Product Details
Customization: Available
Chamber Volume: 30L100L 200L Hydrogen Peroxide Gas Plasma Steriliz
Transport Package: Export Standard Packaging for Air and Sea

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2011-12-26
Management System Certification
ISO 9001, ISO 9000, ISO 13485
Find Similar Products

Basic Info.

Model NO.
MCS-MJG
Origin
China (Mainland) Guangdong
Production Capacity
5000

Product Description

 Low Temperature H2O2 Plasma Sterilization Equipment 30L100L 200L 

Model: MCS-MJG 
Low Temperature H2O2 Plasma Sterilization Equipment 30L100L 200L
Low Temperature H2O2 Plasma Sterilization Equipment 30L100L 200L
 

Advantages

  • •    The technology can reach complete sterilization in 17 minutes (MJG-50 bench top)
  • •    No booster needed
  • •    No need for gas pipe and related device like EtO sterilization
  • •    No hazardous residue for environment and human being
  • •    A new sterilization technology would dominate at least ten years in sterilization field
  • •    The chamber is vented and the products are removed with no residuals
  • •    Product can be used directly
  • •    Process temperatures can be set to between 35-55°C
  • •    Process parameters such as temperature, pressure, power, voltage are measured
  • •    Biological Indicator is Stearothermophilus Bacillus 
    (ATCC7953 or SSIK31 strain)
  • •    Processing cycles are validated utilizing the system software features according to DIN EN ISO 14937 

Specifications: 

Plasma Sterilizer Technical Specifications Comparison

 

Performance Index

MJG-50 (bench top)

MJG-100

MJG-200

Device Type

Class IIa

Class IIa

Class IIa

Total Volume

33L

124L

245L

Available Volume

30L

100L

200L

Power Supply

AC220V±22V  50-60Hz

Standard Single Phase

3 Wire System

AC380V±38V  50Hz±1Hz

Standard Three-Phase Five-Wire System

Duty Type

Short time loading, continuous duty

Sterilization Time

Short Cycle: 17mins

Standard Cycle: 31mins

Short Cycle: 31mins

Standard Cycle: 55mins

Short Cycle: 45mins

Standard Cycle: 70mins

Maximum Input Power

1500W

2800W

4500

Constant Temperature Power

700W

1100W

2200

Standby Power

Approx. 25W

Approx. 160

Runtime Environment Temp

5°C~35°C

Runtime Environment Humidity

30%-95%

 Environment Pressure

70hPa-106hPa

Installation Method

Bench top

Free standing with caster

Injection Method

Cassette with independent H2O2 capsules

H2O2 Dosage

Short Cycle: 1.8ml/Cycle  Standard Cycle: 2.1ml/Cycle

Short Cycle: 2ml/Cycle  Standard Cycle: 4ml/Cycle

Short Cycle: 2ml/Cycle  Standard Cycle: 4ml/Cycle

Loads for Each Cassette

Short Cycle: 12 Cycles

Standard Cycle: 6 Cycles

Short Cycle: 6 Cycles  Standard Cycle: 3 Cycles

Chamber Working Temperature

35°C~55°C

The Minimum Vacuum Degree

50pa

 

 

Chamber Shape

Rectangular

Shape Dimension

670 x 820 x 630

800 x 1002 x 1730

1000 x 1100 x 1790

Package Dimension

850 x 985 x 850

950 x 1150 x 1860

1160 x 1260 x 1950

Minimum Installation Space

1000 x 1000 x 1500

1400 x 1400 x 2000

1500 x 1600 x 2500

Chamber Dimension

220 x 180 x 600

450 x 400 x 690

680 x 450 x 800

Instrument Tray Dimension

600 x 188 x 25

360 x 650

615 x 760

Instrument Tray Numbers

2 shelves 4 layers

Loading Capacity

20Kg, 10Kg/Layer

20Kg/Layer

Net weight

135Kg

490Kg

685Kg

Gross weight

165Kg

590Kg

760Kg

Chamber Material

Aluminum

Shell Material

ABS

Suggested Maintenance Cycle

Half a Year

Screen

6.5 inch, TFT true color, touch screen

Printer

Built-in printer

Data recording and checking

Record and inquire at any time

Foot-kicking Chamber Door Switch

N/A

Optional

Built-in Biological Incubator

N/A

Optional

 

Application Range

 

It is especially applicable for heat and humidity sensitive instrument because it works under dry and low temperature sterilization circumstance.

Materials and sizes of medical instruments could be sterilized in the sterilizer:

l  Stainless steel lumens with one end closed:

diameter ≥1mm, length ≤300mm

l  Stainless steel lumens with open ends at both sides:

diameter ≥1mm, length ≤600mm

l  Polytetrafluoroethylene (PTFE) lumens with open ends at both sides:

diameter ≥1mm, length ≤2000mm (NOTE: Flexible endoscopes NOT included.)

 

*The sterilizer can sterilize 10 lumens in one load without any extra booster.

 

Incompatible Instruments

 

l  One-off articles.

l  Liquid or powder materials.

l  Hygroscopic articles or instruments.

l  Fibrin material & wood pulp material instruments like cotton, paper, cardboard, flax, gauze, sponge.

l  Paper statistical forms or mucilage glue labels.

l  Items with Nylon® exterior.

l  Vacuum-unbearable instruments.

l  Surface Extruded items.

l  Dead ends lumen instruments.

l  Instruments cannot be immersed, hard to clean or unsuitable.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More