Basic Info.

Model NO.
MCL-GH01
Certification
ISO13485
Group
All
Hmocytometer
Good Quality
Hba1c Analyzer
Good Service
Glycated Hemoglobin Hba1c Analyzer
Fast Delivery
Size
408*390*230mm
Weight
8kg
Photometer
415nm LED Integral Flow Colorimeter
Sample Volume
5UL Whole Blood for Each Sample
Testing Scope
3%-18%
Transport Package
Standard Packing for Export
Specification
CE
Trademark
MeCan
Origin
Guangzhou
HS Code
9001200001
Production Capacity
1000 Per Month

Product Description

Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Model: MCL-GH01

Accurate Principle of Methodology
Adopts classical and accurate principle of methodology - Ion exchange liquid chromatography, It is the gold standard of HbA1C analysis, and it is the only analysis method to really separate HbA1C directly by measuring the piecemeal absorbance through continuous test on line,? and obtain the correct area percentage with integration.


Accurate separation 4-gradient elution
The novel 4-gradient elution for HbA1C can separate accurately glycated hemoglobin with 4-gradient elution of corresponding concentration reagent aiming at HbA1C instead of routine ?elution process produced by high and low concentration mixture.

High Separation Liquid Chromatographic Column
High separation liquid chromatographic column made of imported resin with volume of Φ 9mm x 45mm and weight of 2.5g which is 15 - 20 times greater than general micro chromatographic column. High efficiency chromatographic column for 300 tests ensure the accuracy of test results.

High Sensitivity 415nm LED Integral Photometer
High sensitivity 415nm LED integral photometer has the characteristics of correct wavelength, stable light source, full aluminum alloy structure, high anti-interference performance, multi-lens focusing, micro cuvettes and high sensitivity. It can record accurately analysis curve.

Supply with Original Calibrator
The international standard value tracing is adopted. The authoritative reference material for quality control is used to transfer the numeric value. Each set of reagent is supplied with two sets of calibrator for proper calibration so as to ensure that the test results are correct and reliable and thoroughly to avoid individual error caused by factor calibration.


Precision Chromatographic Column and Thermostatic Apparatus
Precision chromatographic column and reagent thermostatic control apparatus ensure that Chromatographic column and reagent are not affected by environment temperature and effectively guarantees the repeatability and correctness of the test results

Specification:
Testing Method Low pressure ion exchange liquid chromatography
Testing Item Glycated hemoglobin HbA1c
Testing Scope 3%-18%
Testing Parameters Precision(CV)≤3%, Accuracy(V) ≤1.50%
Testing Time 4 minutes(reporting), Full-processing 6 minutes(including cleaning column and recovery time)
Sample Type Venous blood(EDTA anticoagulation), Peripheral finger blood
Sample Volume   5ul Whole blood for each sample
Functional Parameters
Photometer 415nm LED Integral flow colorimeter
Sampling mode Fully-auto 20 position sample turntable
Testing mode Auto test for batch, single test for emergency
Calibration Optional selection of 2 points or 4 points calibration, optional selection of manual or automation, Equipped with 2 groups of high and low level calibrators
Thermostatic control Column and reagent thermostatic control: 25 ±0.5ºC
Reagent matching One piece of column and reagent consumable/300 pieces of testing samples
Reagent allocation Each standard package inclues A, B, C, D eluent, calibrator, hemolytic agent, pump tubing
Output Parameters
Display 320×240 LC Graphic display, displaying real-time testing curve
Printer 58nm Thermal printer, printing testing curve and report
Report Output IFCC concentration value, NGSP area percentage, ADAG average glucose
Data storage 1000test report(including testing curve)
Communication interface RS232 communication interface, connecting to HIS/LIS system
Working Parameters
Power Supply AC220V±22V, 50HZ, 65VA
Size 408*390*230mm
Weight 8KG
Working Environment Temperature 12-30ºC, Relative humidity ≤85%
          

Analyzer Hba1c Instrument Glycated Hemoglobin Hba1c Analyzer
Reagent Standard Package Including QC, Calibrator, column, 400tests reagent

Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer
Hmocytometer Full-Auto Glycated Hemoglobin Hba1c Analyzer Glycated Hemoglobin Hba1c Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More