Surgical Diathermy Machine, Electrosurgical Unit/Cautery Machine for Sale (MC-9651B)
Scope of application
It is applicable to the disease of dermatology, archos-bowels, gynecology and ophthalmology Dept. such as condyloma acuminate, flat wart, plantar wart, verruca vulgaris, ephelides, adenoma sebaceum, internal hemorrhoid, external hemorrhoid, cervical erosion, Na-cyst, cervical polyp, nympha cyst, chronic hypertrophic rhinitis, nasal polyps and nasal cavity angioneoplasm, etc.
Function Features
Import integral circuit and control chip to ensure the normal application of the apparatus.
Spherical electrodes, needle-shape electrodes, wire electrode and knife-shape electrodes, easily-used operating handles, excellent quality.
Integrating several new technologies to ensure the integral features of quick startup, high efficiency, long-fire life and stability.
New technology related to switching power supply to save the necessity of external AC voltage stabilizer; normal application is enabled to area with unstable power supply(198V~242V).
Technical parameters
Working mode: ionization, blood clotting, mixing cut
Operation style: To press correspondence button to convert according to treating needs
Power supply: a.c.220V±22V,50MHz±1MHz
Working frequency: 1.27MHz ±10%
Output power: mixing cut: 40W±20%, blood clotting: 30W±20%, ionization: 15W±20%
Power indication: 240VA
Handle quantity of treatment: one
9651A High Frequency Electrocautery
Scope of application
It is applicable to the disease of dermatology, archos-bowels, gynecology and ophthalmology Dept. such as condyloma acuminate, flat wart, plantar wart, verruca vulgaris, ephelides, adenoma sebaceum, internal hemorrhoid, external hemorrhoid, cervical erosion, Na-cyst, cervical polyp, nympha cyst, chronic hypertrophic rhinitis, nasal polyps and nasal cavity angioneoplasm, etc.
Technical parameters
Working mode: long fire, short fire
Operation mode: Switch of long fire / short fire
Power supply: a.c.220V±22V,50MHz±1MHz
Working frequency: short fire mode:0.95MHz ±10%, long fire mode:1.27MHz ±10%
Output power: short fire mode: 18W±20%, long fire mode: 14W±20%
Power indication: 120VA, step display
Handle quantity of treatment: Two
2001T 80 Microwave Therapy Instrument
Scope of application
Applicable for the treatment of hypertrophic rhinitis, rhinorrhagia, chronic phryngitis, internal hemorrhoid, external hemorrhoid, mixed hermorrhoid, cervical erosion, condyloma acuminate, chronic periapical, periodontitis and physical therapy of wound healing etc.
Function Features
High safety: with hi-tech isolation technology, microwave leakage value is far below national safety limit.
Antistick therapy device: special macromolecule coated device to effectively prevent tissue sticking.
Wide range voltage technique: stable output can be kept under unstable power supply(176~264V).
Long-life Magnetic Control Pipe: High Effective Long-life Magnetic Control Pipe, with service life more
than 30 thousand hours.
Rapid Initiation: Large-scaled IC (built-in CPU) Control
Output Supervision: when output is overload, the instrument would automatically close the microwave
output function so as to protect the safety of doctors, nurses and patients.
Humanity Operation:touched button, macroscopic digit display.
Technical parameters
Ambient Temperature: 5ºC-40ºC,can be used continuous
Working Frequency: 2450MHz±50MHz
Power Output: Treatment mode: 5W~80W, step can be adjusted, Physiotherapy mode: 5W~80W, step can be adjusted
Timing Range of Timer: Treatment: 1s~99s, Physiotherapy: 1min~30min
Power supply: a.c. 220V±22V,50Hz±1Hz
Surrounding temperature: 10ºC~40ºC
Relative humidity: 30%~75%
Atmospheric pressure: 700hPa~1060hPa
2001L 80 Microwave Therapy Instrument
2001 series of Microwave Therapy Instrument is a medical device to act on human body with the particular biological effect of microwave for generating non-heat effect and endogeny heat effect. It is broadly used for the treatment and physical therapy in gynecology, otorhinolaryngology, dermatology, stomatology and anal disease.
Scope of application
Applicable for the treatment of hypertrophic rhinitis, rhinorrhagia, chronic phryngitis, internal hemorrhoid, external hemorrhoid, mixed hermorrhoid, cervical erosion, condyloma acuminate, chronic periapical, periodontitis and physical therapy of wound healing etc.
Function Features
High safety: with hi-tech isolation technology, microwave leakage value is far below national safety limit.
Antistick therapy device: special macromolecule coated device to effectively prevent tissue sticking.
Wide range voltage technique: stable output can be kept under unstable power supply(176~264V).
Long-life Magnetic Control Pipe: High Effective Long-life Magnetic Control Pipe, with service life more
than 30 thousand hours.
Rapid Initiation: Large-scaled IC (built-in CPU) Control
Output Supervision: when output is overload, the instrument would automatically close the microwave
output function so as to protect the safety of doctors, nurses and patients.
Humanity Operation:touched button, macroscopic digit display.
Technical parameters
Ambient Temperature: 5ºC-40ºC,can be used continuous
Working Frequency: 2450MHz±50MHz
Power Output: Treatment mode: 5W~80W,5W~120W,5W~200W,step can be adjusted, Physiotherapy mode: 5W~80W, step can be adjusted
Timing Range of Timer: Treatment: 1s~99s, Physiotherapy: 1min~30min
Power supply: a.c. 220V±22V,50Hz±1Hz
Surrounding temperature: 10ºC~40ºC
Relative humidity: 30%~75%
Atmospheric pressure: 700hPa~1060hPa
Please contact me for more information of Surgical Diathermy Machine, Electrosurgical Unit/Cautery Machine for Sale (MC-9651B)