Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model: Sonoscape E2
E2 provides wide range of applications to assist users for routine scanning.
Auto Image Optimization
With the press of a button the image is automatically adjusted and optimized, saving you time with parameter adjustments. Additionally, with Auto Focus on, the focus area follows the depth of the ROI box as it is moved in the scanning field, providing users an excellent image quality in the desired area of interested.
Item | Specified |
General Requirement | |
Released with in 1 years | released at least at 2017 |
Operation System | Linux Platform(stable and will not infect by virus) |
Size | maximum: L×W×H(mm): 352mm×378 mm×114mm |
Weight | Less than 6.5kg |
Multiple Beam Processing | required |
Applications | have a wide range of applications includes: abdominal, OB/Gyn, cardiology, urology, small parts, vascular, orthopedic, anesthesia and MSK. |
Application icom | All the applcation shows in unique icom |
Monitor | no less than 15.6 inch,LCD monitor, widescreen,anti-flickering, can be vertically and horizontally swiveled |
Keyboard | PC back light Keyboard on the control panel |
Monitor and Key botard Bright Auto Adjustmen | Monitor and Keyboard Bright Auto Adjustmen |
WIFI connection | required |
Solid State Diver(SSD) | can be choosed in optional |
Fast Boot up | With in 30s |
Stand by | required |
Operation Mode | B Mode |
Dual B | |
Quad B | |
Color Doppler | |
Directional PDI | |
TDI | |
Power Doppler Imaging | |
SR Flow Imaging | |
Dual-Live | |
Pluse inversion Harmonic Imaging ( PHI ) | |
Trapezoid Imaging (Linear And Convex) | |
Real-time Panoramic Imaging(B mode ) | |
M Mode | |
Anatomic M Mode | |
Color M Mode | |
PW ,CW | |
Duplex: B/M, B/PW, can be defined in new preset | |
Screen Zoom | |
Compound Imaging (1,2,3,4) | |
u-scan(Speckle Reduction) | |
Needle enhancement ( Vis-needle ) | |
Transducer Socket | 2 active transdcuer connectors, which can support all transducers. |
Transducers | can supply with more than 10 transducer choices, covering linear, convex, endocavity, phased array, micro-covex and intra-operation probe. |
Scanning Methods | Electronic Convex Secter Electronic Linear Secter Electronic Phased Array Sector |
ECG | support ECG function |
Clipboard Function | Capture and reviewthe archived images, support output the images and viedo to USB and DVD in scanning interface |
Image Optimization | Images can be optimized by one button in B mode and PW mode |
TGC | required |
LGC | required |
Zoom | The zoom value can be shown.The minimum zoom ratio can low to 0.8. The max zoom ratio can up to 10. |
Full Screen Zoom | required |
Auto foucs | required |
Biposy | support 2 needle guide line and 1 gun guide line |
Warranty | spare parts should be provided with system for 18 months |
Scanning Parameters | |
B Mode | |
Dynamic Range | at least 20-280dB(Probe dependent) can be adjusted by 20dB/step. |
Gain | 1~255, adjustable |
Depth | 40cm Maximum |
Chroma | Maximum 12 selectable |
Frequency | 5 bands |
Persistence | Low, Med, High, Max 4 levels |
Grayscale curve | 16 types |
Line Density | can choose the lower line density for higher frame rate, and line density can be adjusted by 3 levels: low/med/high |
u-scan | Speckle Reduction Imaging,adjustable |
Compound Imaging | required,adjustable |
Live Panoramic imaging | required |
Trapezoidal imaging | Image area extend for linear |
Convex extension | Image area extend for convex |
Biopsy guide function | required,and the biopsy line adjustable. |
Imaging width and position | adjustable |
Tissue Specific Imaging | provide different choices for tissue scanning when scanning in different orgens |
Image Optimization by one button | required |
B-steer | required,at least the Linear probe |
Color Doppler Mode | |
Frame Rate | up to 209 f/s |
Auto foucs | required |
Pulse Repetition Frequency | 0.5~10KHz |
Steer Angle | up to 16 degrees |
Wall filter | 5 levels, Min, Low, Med, High, Max adjustable(Probe dependent) |
Baseline | ±4 steps, adjustable |
Persistence: | 4 levels, Off/Low/Med/High/Max adjustable (Probe dependent) |
Image orientation | left/right, up/down |
Flow Invert | required |
Color /Direction energy | at least 7 kinds,selectable |
SR Flow | Highly sensitive blood flow detection technology |
Line density | can be adjusted by 4 levels:min/low/medium/high |
B and Color Flow Simultaneous Realtime Display | required |
M Mode | |
Sweep Speed | adjustable, at least 5 levels |
Video Inversion Function | required |
Chroma | at least 12 types |
Display Format | at least 5 types |
Steer M | up to 3 lines |
Spectral Doppler | |
PRF | PW : 1~16KHz CW: 1-50KHz |
Maximum Velocity Range | PW: 0.0576 - 6.14m/s CW: 0.0761 - 10.35m/s |
Baseline | 9 steps |
Frequency | 3 bands |
Angle Correction | 0~88 degree, 2 degree per step or less |
Auto Angle Correction | Auto 60 degree of Angle correction by one botton |
Sample Volume in PW Doppler | 0.5~24 mm, adjustable |
Sweep Speed | adjustable, at least 5 levels |
Chroma | 12 types |
Video Inversion Function | required |
Spectrum Inversion | required |
Real Time Auto-Trace | required |
Wall Filter | 5 levels, Min, Low, Med, High, Max, adjustable |
One-key Auto Optimization | At least can adjust the baseline, PRF |
Steer angle | 4 levels: 0°, ± 8°,± 12°, ± 16°, adjustable |
Auto foucs | required |
Display Format | 5 |
Transducer | |
Transducer Warranty | transducers are manufactured by supplier, and the warranty should last 18 months |
Transducer Frequency | broadband (1.0~16MHz) with multiple 5 frequencies range in B Mode/Color Mode/PIH Mode/PW mode/CW/Mode |
Transducer Elements | at least 128 |
Linear Transducer | frequency range: 4~16MHz |
Convex Transducer | frequency range: 1~15MHz |
Endocavity transducer | frequency range: 3~15MHz scanning angle: 135°, can extend to 193° |
Phased Array | frequency range: 1~9MHz |
Biopsy Guide | Required |
Image Storage | |
Cine Loop | available for all mode |
Retrospective Storage | 27s retrospective saved in real time |
Prospective Storage | 480s prospective saved in real time |
Freeze Storage | required |
Image Format | JPG, BMP, TIF |
Clipboard function | is avilibale in frozen B mode |
Clip Format | WMV, AVI |
One Key Save | required |
Doppler cine playback | speed is adjustable, sound can be played back |
Print&Store Region | Full Screen, Image&Result Area, US Image |
Image Share Service | required |
Store To UsbDisk | required |
Storage Capability | Hard Disk can up to 500G/1T; SSD can up to 128GB |
Report Tables | Abdominal, OB/Gyn, Cardiology, Urology, Small Parts, Vascular,IMT |
Report Format | TXT, PDF |
Report Templet | at least 6 images can be displayed in report |
Measurements | |
Measurement Packages | Abdominal, OB/Gyn, Cardiology, Urology, Small Parts, Vascular, Orthopedic, and measurement packages can be chosen for Icon Driven or All Packages |
Measurement in B Mode | required |
Measurement in M Mode | required |
Measurement in PW Mode | required |
Short cut key for obstetrics measurement | required |
Quick Measurements | Measurement can be select by one button |
IMT Measurement | support IMT measurement, and the result can be displayed in report |
Obstetrics Packages | |
Measurement items | Including GS, CRL, BPM, HC, AC and AFI. |
Formula | users can define the formula by themselves |
Fetal Growth Chart | required |
Cardiac Packages | |
B Mode | required |
M Mode | required |
PW Mode | Real Time Automatic Measurement |
Annotations | |
Comments | users also can define it by themselves |
Arrow | Orientation adjustable |
Body Mark | Classified by specific exams |
Input and Output | |
DVD-R/W | Required |
Footswitch | Required |
S-video output | Required |
USB Port | 3 ports |
VGA/HDMI output | Required |
Printer interface | Video printer |
Ethernet port for DICOM | Required |
Preset Function | |
Preset Function | Required, can be customized |
User Define Key | Required, can be customized |
The sequency of presets | Users can arrange the presets |
import or export presets | Required |
Laguages support | |
System Laguages support | English, Simplified Chinese, Spanish, Russian, French, Italian, Germany, Norwegian,Portuguese |
Qualification documents | |
CE certification | Required |
ISO 13485 | Required |