Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
15-inch, 800x600 color TFT, multi-channel display with up to 13 wave channels for detailed observation.
Advanced SpO2 with DSP algorithm ensures top-notch performance during movement. SpO2 features Perfusion Index (PI) for exceptional accuracy even in low perfusion scenarios.
Innovative NIBP VET algorithm supports a wide range of animals, from small cats to horses, with robust over-pressure protection.
Distinctive human voice alarm for immediate and clear notifications.
Standard RJ45 network connectivity, with an optional USB WIFI module for effortless connection to the Central Monitoring System (CMS).
USB data output enabled, with accompanying software for seamless data review on a computer.
Gas module intelligently auto-detects 5 types of anesthesia gases: HAL, ENF, ISO, SEV, and DEV.
Versatile screen layouts, including a Big Font screen. Parameters and waves can be toggled on or off for each accessory cabinet.
Technical Specifications
ECG | SPO2 |
Lead : 3/5 | SpO2,PR,PI |
5 lead mode: I, II, III, aVR, aVL, aVF, V | Accuracy: ±2%( 70~100%) |
3 ECG channels, 7 ECG waves in ECG full lead mode | Pulse Rate: 20~250bpm |
HR:15-500BPM | Temperature |
Gain : X1/4,X1/2,X1,X2 | Channel : 2 |
Wave speed : 12.5/25/50 mm/s | Measure and Alarm Range0 - 50°C |
Pacemaker | Sensor type : rectal |
Arrythmia analysis | Unit : °C |
ST analysis | Accuracy : ±0.1°C |
Filter mode: other, monitor, surgery | Recorder |
RESP | 3 channals |
Impedance between RA-LL or RA-LA | Storage |
RESP lead : I/II | ≥720 hours trend graph and trend table |
Wave speed : 6.25, 12.5, 25mm/s | 2 houss wave review |
Apnea Alarm,5~120s | 200 alarm review |
NIBP | Alarm |
Method : Oscillometry | 3 levels alarm |
For animal from <10kg to > 20kg | All the alarm limit can be adjusted by user. |
Unit : mmHg ,Kpa | Unique Voice alarm |
Mode: Manual,Auto,STAT | IBP |
Measure and Alarm Range | Sensor: OHMEDA or BD, EDWARD compatible |
SYS 40~280 mmHg | Channels: 2 |
DIA 10 ~220 mmHg | Measuer Range: -50~ 360 (mmHg) |
MEAN 20 ~ 240 mmHg | Accuracy(no sensor): ±2% or £1mmHg, use the greater |
Cuff 0 ~ 300mmHg | CO2 |
Static pressure: ±3mmHg | Measuer Range: 0%~13% |
Automatic measurement interval time: | Accuracy: ±2 mmHg @<5.0% COz (at ATPS) |
1 minute ~ 480 minutes | Breath Rate: 3- 150 bpm |
Standard:
ECG, NIBP, SpO2, PR, TEMP, RESP
Optional:
Mainstream/Sidestream EtCO2,
GAS, IBP-1/IBP-2, Thermal Recorder,
Wall Mount, Trolley, CMS