MCL-200BS
Series No. | Name | Series No. | Name |
1 | Power adapter plug | 2 | Display window |
3 | Power button | 4 | Unit indication light |
5 | Unit shift | 6 | Shading cover |
7 | Measuring cell | 8 | Battery box |
9 | Enter | 10 | CAL(calibration) |
11 | Backlight |
Applications
The instrument widely apply to the turbidity measurement in power plants. waterworks. life sewage treatment plants. drink factories. environment protection departments. process water. brewage and drug manufactures departments. Hospitals and so on.
Instrument Principle
This instrument is compared with measured solution and standard calibration solution and it based on the principle of color intensity values. After placed measured solution in the measuring cell, light resource issued by a particular light bean and in face of the dissolved substances simultaneously a part of beau's is absorbed
(Absorbance=light source total flux-the amount of light through). Then it will as a signal of circuit apparatus of receiving. amplification, derived from the value after treatment and then compared with the standard solution.
Characteristics
-The large bright LCD makes the reading more comfortable, effective avoid natural light influence.
-The succinct operation. broad measuring range and high cost performance ratio. can suit to various professional applications.
-The unique localization structure and high accuracy optical path system effectively guarantee the measuring value correctness and repeatability.
-Low drift. high accuracy. stable circuitry system and high effective longevity light source all ensure the instrument running stable and long time.
-Low consumption and AC/DC power supply. compact design easier for operating outside or laboratory.
-With low voltage indication function remand of users to replace battery timely to ensure the measuring value accuracy and effectively.
Specifications
Model |
MCL-1000BS |
|
Resolution (NTU) |
0.1 |
|
Measurement Range (NTU) |
0-400.400-1000 |
|
Zero drift |
±1.5%F.S (NTU/30min) |
|
Indication Stability |
±1.5%F.S (NTU/30min) |
|
Repeatability |
2% |
|
Basic Accuracy |
±8 %(0-20NTU) |
±6 % (> 20NTU) |
Power Supply Oscillation Influence |
0.5 % F.S |
|
Power Requirement |
DC 6V |
|
Storage Requirement |
Temperature 0-45°. humidity < 85%. |
Operating Environments
a, Operating Temperature: 0-40°C :
b, Operating Humidity Range: less than 80%RH:
c, Power Requirement: Power Adapter or 4pcs AA alkaline dry battery
d, The instrument should be placed on a table that is free of vibration and avoidance the direct light effectively.
e, Enough space should be remained around the instrument in order to help the radiation and no intense vibration source and strong magnetic filed disturbance.
f. No obvious dust and caustic gas in the surrounding air.