Customization: | Available |
---|---|
Type: | Biochemical Analyzer |
Syringe: | Biochemistry Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Description
MCL-SMT-100V is a portable automatic chemistry analyzer which is applied to clinical biochemistry analysis with lithium heparin anticoagulant whole blood, serum and plasma. And MCL-SMT-100V covers various applications from emergency departments to clinical labs, from ICU to surgery centers, from anesthesia department to respiratory care, from home to ambulance.
In addition, the MCL-SMT-100V system consists of a 5-kg portable analyzer and pre-configured reagent, or "rotor", disks that enable veterinarians to obtain a clear, comprehensive picture of a patient's condition, and veterinarians needn't add reagents by themselves.
Advantages
Simple operation
Free of centrifugation, water treatment system and professional doctor. Anyone can operate only by 3 steps. Add 100ul whole blood into disc, put disc into analyzer and delay 12 minutes to print report.
Little sample volume
Sample volume is 10-20% of normal chemistry analyzer.
Accurate Result
Test sample and dilution volume measured by mould, without random error.
No carryover
Portable,5 Kg, 0.02m3
Provide with AC and DC power, suitable for use at movable place and outdoor.
Free maintenance
Auto QC and real time Calibrate.
Stroboscopic xenon lamp, service life is over one hundred million times.
No internal fluid flow, no pump and valve, decrease machine fault.
Specification
Sample type | Anti-coagulation whole blood, serum, plasma |
Sample volume | 100ul |
Bar code | Two-dimensional bar code |
Testing time | 12mini/person |
Testing principle | absorption spectroscopy, transmission turbidimetry |
Testing method | end point, kinetic, fixed time, turbidmetry, etc. |
Temperature | 37 ±0.2 degrees celsius |
Absorbance | 0-4.5Abs |
Resolution | 0.001Abs |
Carryover | 0 |
QC & Calibrate | auto test in real time |
Work environment | Temperature:10-32 degrees Celsius, Humidity: <90% |
Optic system | Reversed optic. 340nm, 405nm, 450m, 505nm, 546nm, 578nm, 630nm, 850nm |
Light source | 12V/20W,.Tungsten halogen lamp's life span reaches over 2500hours |
Power supply | AC100V-240V,50-60Hz |
Power | 70W |
Interface | 7.0 inch True color LCD touch screen, multi-language choice. |
Vet version is optional | |
Storage | >100000 results |
Printer | built-in thermal printer and external printer |
Data port | 4 USB, 1 RS232. Software upgrade function by WIFI |
Weight | 5KG |
Size | 31cm(H)*21cm(W)*28(L)cm |
Animal types | Over10 species |
Analyzer Uses
3 Steps operation of the dry chemistry analyzers:
Step 1: Add Sample
Simply collect 0.1cc of whole blood, serum or plasma, and transfer it to the self-contained reagent disc. The single use, disposable disc contains all the reagents and diluent necessary to perform a complete fixed multi-test panel.
Step 2: Insert Disc
Follow the touch screen commands. Place the disc into the analyzer drawer, enter requested information and the biochemistry analyzer does the rest. In approximately 12 minutes, results are ready.
Step 3: Read Results
Complete panel results including patient demographics, chemistry concentrations, reference ranges, sample integrity indices and iQC are available on the full color display, printed on a self-adhesive print out, transmitted to an external printer, The automatic biochemistry analyzer will store on-board up to 100000 patients and quality control results.
Product Description
The dry chemistry analyzer is an instrument that uses the serum of centrifuged blood sample, and induces reactions using reagents to measure various components, such as sugar, cholesterol, protein, enzyme, etc.
These tests are performed for routine health checks or at hospitals, and the results provide objective data enabling early detection and diagnosis of disease, as well as indicating the effects of treatment and patient prognosis.
The dry chemistry analyzers feature:
Portable small size, 5kg, 0.02 m3, suitable for use at movable place and outdoors,
Simple operation, free of centrifugation, water treatment system and professional doctor, anyone can operate only by 3 steps, Little sample volume, sample volume is 1/12 to 1/10 of traditional chemistry analyzer, Accurate result, test sample and dilution volume measured by mould, without random error, no carryover.
Advantage
Freeze-drying reagent, disposable package, storage life as long as 1 year,
Internal autonomous channel design, disposable disc avoid carryover,
Multi reagent disc for choose.
The Types of Animal Biochemistry Reagent Disc | |
1.The 14 Comprehensive Diagnostic Parameters: | K+, Na, ALT, ALB, ALP, AMY, TBIL, GLU, GGT, CHE, CREA, TP, UA, UREA, GLOB* |
2.The 13 Health Check Parameters | ALT,ALB, AST, AMY, CA, CREA, GLU, TBIL, CK,TG,UREA, PHOS, TP, GLOB* |
3.The 10 Emergency and Severe Disease Parameters | K, Na, Cl,TCO2, ALT, AMY, GLU, UREA, CREA, CHE |
4.The 9 Liver Function Parameters | ALT, AST, ALB, ALP, TBA, TBIL, GGT, TC, TP |
5.The 8 Kidney Function Parameters | CA, PHOS, TCO2, ALB, GLU, UREA, CREA,UA |
6.The 7 Electrolyte Parameters | K+, Na+, Cl, CA, TCO2, Mg, PHOS |
7.The 9 Pre-operation Test Parameters | ALT, ALP, AST, GLU, UREA, CREA, TP, LDH, CK |
8.The 11 Birds and crawlers | K+, Na+, CA, PHOS, ALB, AST, CK, TBA, GLU, TP, UA, GLOB* |
9. The Others | It is workable to customize according to your request. |
Packaging & Shipping
The product was strong export package & suitable for deliver by air, express or sea.
1. Express: Ship it by UPS/ DHL/ FEDEX/ TXT express which is door to door. (3~5 days)
2. Air: Ship it by air cargo which you need go to airport to take it. (2~7 days)
3. Sea: If goods are large quantity and you are not in hurry, we can ship it by sea to save freigt cost. (About one month)
FAQ
Q: What are the power requirements to operate SMT 100 analyzer?
A: The analyzer requires 100-240 volts AC, 50-60 Hz.
Q: What is the shelf life of the reagent discs?
A: The reagent discs can be stored for up to 12 months at 2-8°C.
Q: Can the expired reagent discs be used?
A: No, the result of the test will be unreliable.
Q: How long can the reagent disc be used after removing from the foil pouch?
A: After opening the pouch, the disc should be used within 20 minutes. Do not place the disc back into the refrigerator for later use.
Q: Can reagent discs be used again?
A: No, it can only be used once. It is a single-use disposable reagent disc. One disc one sample.
Q: What types of samples can be used with the SMT 100 analyzer?
A: The sample can be whole blood, plasma or serum.
Q: What is the sample volume required for a test?
A: 100ul is required to run a test. In case of rechecking, it is recommended that collecting blood sample is not less than 250ul.
Q: Before testing, does the reagent disc need to take out from refrigerator to guarantee the test temperature?
A: Yes, to avoid congealing and guarantee test temperature, before unpack and test, reagent disc
have to be placed 20 minutes after taking our from refrigerator or low temperature storage tank.
Q: In the process of sample and control test, when clicking STOP button, can the test disc be used as a new disc again?
A: The stopped test disc can't be used again. If it is not must situation, please don't stop it.
Q. Do the users need to add reagent?
A: No, the reagent is already packed well in each of the disc hole before packing foil pouch.
Q: How to maintain the instrument?
A: Keep the instruments shell and drawer clean. Compared to the traditional analyzer, our instrument has less maintenance.
ANALYZER COMPARISON
CHEMISTRY ANALYZERS COMPARISON | SEMI-AUTO | FULLY-AUTO | DRY CHEMISTRY | MCL-SMT-100 SERIES |
SIZE AND WEIGHT | Small and Light | Big and Heavy | Small and Light | Small and Light |
ADVANTAGES | Cheap and Small Size | Accurate for Quantity Samples Test | Cheap and Fast for Single Parameter Test | Fully Automatic No Carryover for Reagents Easy Use Small Fast and Accurate for One Sample Multiple Parameters Test |
DISADVANTAGES | Too Complex in Operation and Carryover Pollution | Complex in Operation and Carryover Pollution Big Size | Few Parameters and Not So Accurate for Testing | Not Economic for Single Parameter Test |
APPLICATIONS | Clinics Hospitals Labs | Hospitals | Clinics Hospitals Labs Emergency Animals POCT | Clinics Hospitals Labs Emergency Animals Army Marine POCT |
FULLY HEALTHY CHECK NEED BLOOD | 2-5 cc | 2-5 cc | 0.1 cc | 0.1 cc |
Company Information
Our MeCan is high-tech enterprise of high quality and minded entrepreneurs, and integrates the R&D, manufacturing, sales and service about the IVD products.
The group, which owns advanced technology, excellent production, considerate sales and services, has been sparing their heats and soul to service each of our old and new clients from home and aboard.
In the spirit of surviving by brilliant quality, developing by sincerity and trust, with the excellent products, competitive price and perfect service, our MeCan is continuously and steadfastly attracting domestic and oversea clients, and building long-term stable friendly business development relationship.
To satisfy you is our MeCan people long-lasting pursuit.
Our Certifications
MeCan has certificates including: ISO13485:2012 Quality Management System issued by TUV CE Declaration of Conformity listed by TUV as IVD device Free Sale Certificate issued by China Council for the Promotion of International Trade China Chamber of International Commerce Patents (We are the only manufacturer of this kind of chemistry analyzer in China, we found some companies stolen our product pictures, MeCan will protect our right.)
We offer all vet clinic equipment: vet table, vet cage, vet infusion pump, vet injection pump, vet surgical instrument, vet ECG, vet monitor, vet ultrasound,vet x-ray machine and accessory, vet laboratory analyzer, Pet Treadmill, vet mortuary equipment, etc.
Please Send inquiry to us for the veterinary dry chemistry analyzers
Contact Person: Joe Jiang
Tel: (+86)-20- 8483 5259