Material: Stainless Steel
Color: White
Product Name: Medical
Transport Package: Carton Wooden Case Crate
Trademark: MeCan
Origin: China (Mainland) Guangdong
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
MCS-3008
Production Capacity
5000

Product Description

Operating table operation bed

MCS-3008
Operating Table Operation Bed

 

MCS-3008 is hydraulic mechanical operating table. The table up-down is hydraulic controlled.

The table top are all stainless steel 304, which is durable and convenient for clean and disinfection.

Main Specification

Length/Width 2080mm/480mm
Height 750mm-1000mm
Trendelenburg/ Revers Trendelenburg ≥25°/≥25°
Lateral Tilt ≥18°/≥18°
Head Section Up/Down ≥45°/≥90°
Leg Section Up/ Down/ Outside ≥15°≥90°/≥90°
Back Section Up/ Down ≥90°/≥10°
Kidney Bridge Lift 120mm
Load Capacity 250kg

 

 

 

Description
Use and brief introduction
MCS-3008 is designed specially to meet the different demands of the market and according to the common advice of users.
The operating table is used for chest/surgery/otorhinolaryngology/ gynecology and obstetrics/urology/orthopedics operations.
it uses pedal-operated oil pump to control its elevation (up/down),easy to operating and it is reliable. Because the operating table is all mechanically be operated, so it wouldn't be influenced by power cut, which is more reliable and safer.
The operating table is widely used, easy to be operated and adjusted with reliable performance, which is an ideal table for different hospital. 
Be sure to read the instruction carefully before using, and keep it.
Gen eral content
Basic data     

basic/data Model length Width Height range Distance of elevation
  L W h min S
MCS-3008 ≥2080 480±20 790±50 ≥240

Gorss weight,net weight,volume
Gross weight 255kg,net weight 205kg,Volume(length×width×height)1280mm×750mm×1030mm.
Safe working load
The safe working load of the table is 173kg

   back plate        seat plate          leg plate          Summation
       50kg            98kg             25kg             173kg

Product information
The operating is formed by head plate and back plate, waist plate, seat plate and leg plate

 

-Anesthetic screen;-shoulder support;-arm support;-body support;-leg support;-Cushion;

1-Head plate;2-Control Handle;3-Elevation pedal;4-Brake;5-back plate;6-kidney bridge;7- seat plate;8-base;9-Leg Plate;10-Foot plate.

Feature

You can adjust the height of the table as you wish,convenient position for operating personnel.
You can take the cushion apart from the table for cleanup.
Commissioning
Keeping
Inside its original packing the operating table may be exposed for a period of 15 weeks to environmental conditions within the limits of 

         Ambient temperature                        -30ºC~55ºC
         atmospheric humidity                            ≤95%
         Atmospheric pressure                  500 hPa~1060 hPa

The table should be kept in a clean place, never put in the places where influenced by atmospheric pressure, temperature, humidity, aeration, sunshine, or dust and sulfur.
The table should be kept separately from chemicals.
stock in a ventilated place.
Transportation
Upon leaving the factory, the operating table are positioned fit for transportation. In case of further transportation at a later date, we recommend to adjust the operating table into the same position.
In order to transport the operating table, adjust seat and back section in to horizontal position.
Remove the head and leg plates, and detach other accessories.
Adjust the table-top into minimum height.

Should choose anti-static cushion.
Please check the operating table all the times.
Once found it out of work ,please stop using.
Make sure that the patient won't touch the table.
Please don't take them down when they are out of work, contact the serviceman in time.
It should be separated from the magnetic field when using.
Attention before using
please read the instruction before using, people who doesn't know the operating method is forbidden to use.
Attention after using
To return to the former condition.
Clean the table after operations.

Method of using operation table
Preparation before using
No objects exist that affect the operations. 
Move the table to the right place you need.
Lock the base of the table.
Displacement
Moving and locking the operating table
Danger!
The patient may get hurt if the operating table is displaced while he or she is lying on the top in the knee-elbow-position. Do not displace the table with the patient in knee-elbow-position.

Danger!
The patient may get hurt if the operating table is displaced with an attached extension device, due to its reduced stability against tilting. Do not displace the operating table with an attached extension device when a patient is lying on the top.
Using adjust
Elevation(up and down)
The operating table adopts pedal-operated oil pump to control its elevation (up/down), it uses one pedal-operated oil pump to control its up and down.(look at the picture 2). If you want it to go up, please step on it constantly. (Never reach to the limit), If you keep stepping on it to the end, it will be down. But be sure that you won't step too strongly, or it will trans-shape.

Adjustment of table
The trendelenburg/lateral tilt/elevation of back plate are all controlled by mechanical gear.

Adjustment of head plate

Loosen the handle behind the head plate, adjust your ideal position.

Adjustment of leg plate
The leg plate of the table can be turned around, you can also take them apart from the table. There is a handle behind both two leg plate.
Up and down of leg plate, loosen the handle , and then adjust to your ideal position.
Evagination of leg plate, loosen the handle, and then adjust to your ideal position.
If you want to take them apart, just loosen the handles.

mobilization and move of the base
The Immobilization and move of the base use one pedal .When you need it moving, just step on the pedal and keep the pedal down, then it can move. When you need it fasten, you can step on the pedal and keep it up. 
Clean out and disinfection
The cushion should be cleaned twice by 75% alcohol and then use disinfector and ultraviolet radiation for sterilization.
Maintenance
Users should check the table and maintain it from time to time.
When the table hasn't been used for long time, you need to check it before using.
There is enough oil in the oil pump when leave the factory. If you find the oil is not enough, you can add N46 oil.
In order to prolong its using life and keep it in a good condition, you need to pay attention to the daily maintenance and add lubricant oil.
You cannot use caustic cleaner to clean the cushion after operations.
Please lower the lowest position after using.
When it cannot work any more, the scrap of the equipment should comply with legal regulations.

Main technical data
Form 2: Main technical data
Item Basic data 
tabletop Trendelenburg ≥25° 
 Reverse trendelenburg ≥25° 
Lateral tilt(left/right) ≥18° 
Head plate Up ≥45° 
down ≥90° 
Back plate up ≥90° 
down ≥10° 
Leg Plate down ≥85° 
outward ≥90° 
Kidney bridge ≥120mm 
 Packing list 
Form 3 packing list
 NO. Item quantity NO. Item Quantity 
1 Anesthetic screen 1 piece 7 Foot plate(PU) 2 piece 
2 Shoulder support(cushion) 2 piece 8 cushion  1 set 
3 Body support(cushion) 2 piece 9 oilcan(with oil) 1 piece 
4 Arm support(cushion) 2 piece 10 Fixing clamp 2 piece 
5 Leg support(wrapper) 2 piece 11 Sandwich plate   1 set 
6 Head plate(cushion) 1 piece 12 Instruction 1 piece
Operating Table Operation Bed
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now