Defi-Monitor is used to monitor patient's physiological parameters such as ECG,RESP,SpO2,NIBP,DEFI and TEMP continuously. It is intended to be used in various hospital rooms such as Coronary Care Unit,Intensive Care Unit,Neonatal Intensive Care Unit and Operating Room to provide additional information to medical and nursing staff about the physiological condition of the patient.
It is not intended to be used in outdoor transport applications.
What is detail of our monophaisc defibrillator?
Defibrillator type | Manual, Synchronized, Asynchronized |
Out put waveform | Monophasic technology |
Energy accuracy | ∠+1% |
Energy selection | 0, 20, 50, 100, 160, 250, 300, 360 joule (nominal at a resistance of 50) |
Charging time | Maximum 8 seconds to 360 Joules |
Standard Adult/Pediatric Paddles | Reusable external adult paddles(pediatric paddles integrated) |
Power requirements | (a)AC Power supply:110V, 60 Hz /220V,50 Hz (b)Vehicle Voltage:DC 12V |
Internal Battery Backup | (1)Battery type:Rechargeable lead-acid battery (2)Charging time:Time-Minimum of 4 hours for full charging (3)Battery charging:During AC Power Supply operation of the device. (4)Charging /Low Battery Indication:Red LED (5) Battery Capacity:100% of the battery will provide 120 mins of monitoring;and 30 discharges at 360 joules. |
Display | High resolution true-color graphic LED Dimensions 10'diagonal |
ECG | ECG lead: 1.2.3 AVR, AVL, AVF, V1~V6, GND S-T segment analysis: -2.0~2.0mv Arrhythmia analysis: yes Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation |
Respiration | Measurement method: Thoracic impedance |
NIBP | Working mode: Manual/Automatic/stat(5 minutes) Method: Automatic oscillation Cuff type: standard Adult; optional Pediatric/Neonatal |
Temperature | Measurement range 20~45ºC Resolution 0.1ºC |
Pulse Oximetry(spO2) | Display : spo2 value, pulse histogram, waveform, Pulse Range: 0~99%for adult, pediatric and neonatal patients Probe : standard adult finger clip optional pediatric Y-type clip and neonatal wrap Pulse range Pulse range: 0-255bpm |
Standard parameter & configuration | ECG/ RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR |
Optional parameter | 1. Recorder 2. Change be change to lithium battery. |
Main unit | Desktop |
Dimensions | L410xW360xH260 mm |
Weight | 13kg |