12.1 Inch Patient Monitor with Capnography

Product Details
Customization: Available
Screen: 12.1" Color TFT Screen
Medical Equipment: Mcm-9000 12.1 Inch Patient Monitor with Capnograph
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (26)
  • 12.1 Inch Patient Monitor with Capnography
  • 12.1 Inch Patient Monitor with Capnography
  • 12.1 Inch Patient Monitor with Capnography
  • 12.1 Inch Patient Monitor with Capnography
Find Similar Products

Basic Info.

Model NO.
MCM-9000
Display
Multi-Channel Display
Interface
Big Font Interface
Analysis
St and Arrhythmia Analysis
Review
Alarm Review, Arrhythmia Review
Lead Mode
5 Leads (R, L, F, N, C or Ra, La, Ll, Rl,V)
Lead Selection
I, II, III, AVR, Avl, Avf, V
Electrode Offset Potential
±300mv
Baseline Recovery
< 3 S After Defi.
Transport Package
Standard Packaging Is Suitable for Export by Air O
Trademark
Mecan
Origin
China (Mainland) Guangdong
Production Capacity
5000

Product Description

12.1 inch Patient Monitor with capnography 

Model:  MCM-9000 
12.1 Inch Patient Monitor with Capnography
12.1 Inch Patient Monitor with Capnography
 

Features of the MCM-9000 12.1 inch Patient Monitor with capnography:

 

12.1" color TFT screen

Multi-channel display

Big font interface

ST and arrhythmia analysis

Drug dose calculation and titration table

OxyCRG dynamic view display

wi Respiration monitoring th apnea alarms

 

Alarm review, arrhythmia review

Patient info. Input

Anti-defibrillation design

NIBP over pressure protection

Plug-in rechargeable battery, AC/DC available.

Supporting wire or wireless network.

 

Technical Specifications of the MCM-9000 12.1 inch Patient Monitor with capnography:

 

ECG

 

Lead Mode                            5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection                       I, II, III, avR, avL, avF, V

Wavef orm                             2 ch

Lead mode                            3 Leads ( R, L, F or RA, LA, LL)

Lead selection                        I, II, III,

Wave form                              1 ch

Gain                                        2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

 

HR and Alarm Range                      Adult    15 ~ 300 bpm

                                                       Neo/Ped    15 ~ 350 bpm

Accuracy                                        ±1% or±1bpm, which is greater

Resolution                                     1 bpm

Sensitivity                                      > 200 (uVp-p)

Differential Input Impedance         > 5 MΩ

 

CMRR                                   Monitor > 105 dB

                                             Operation > 105 dB

                                              Diagnosis > 85 dB

 

Electrode offset potential           ±300mV

Leakage Current                       < 10 uA

Baseline Recovery                    < 3 S After Defi.

ECG Signal Range                    ±8 m V ( Vp-p )

 

Bandwidth                                         Surgery    1 ~ 20 Hz

                                                          Monitor     0.5 ~ 40 Hz

                                                          Diagnostic  0.05 ~ 130 Hz

Calibration Signal                              1 (mVp-p),  Accuracy:5%

ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting                                   Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review Available

 

Respiration of the MCM-9000 12.1 inch Patient Monitor with capnography:

 

Method                                           Impedance between R-F(RA-LL)

Differential Input Impedance          > 2.5 MΩ

Measuring Impedance Range        0.3~3 Ω

Base line Impedance Range         200~4 KΩ

Bandwidth                                     0.1~2.5Hz

Resp. Rate                                    Measuring and Alarm Range

                                                      Adult 0 ~ 120 Brpm

                                                      Neo/Ped 0 ~ 150 Brpm

                                                      Resolution 1 Brpm

                                                      Accuracy ±2 Brpm

Apnea Alarm                                 10 ~ 40 S

 

NIBP

 

Method                              Oscillometric

Mode                                 Manual, Auto, STAT                       

Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode     5 Min

Pulse Rate Range                           40 ~ 240 bpm

Alarm Type                                      SYS, DIA, MEAN

 

Measuring and alarm range      Adult Mode

                                    SYS 40 ~ 270 mmHg       DIA 10 ~ 215 mmHg         MEAN 20 ~ 235 mmHg

                                                  Pediatric Mode

                                    SYS 40 ~ 200 mmHg        DIA 10 ~ 150 mmHg        MEAN 20 ~ 165 mmHg

                                                  Neonatal Mode

                                    SYS 40 ~ 135 mmHg        DIA 10 ~ 100 mmHg        MEAN 20 ~ 110 mmHg

Resolution                      1mmHg

Accuracy                        Maximum Mean error ±5mmHg

                                 Maximum Standard deviation ±8mmHg

Overpressure Protection          Adult Mode 297±3 mmHg

                                 Pediatric Mode 240±3 mmHg

                                 Neonatal Mode 147±3 mmHg

 

SpO2

Measuring Range                  0 ~ 100 %

Alarm Range                          0 ~ 100 %

Resolution                             1 %

Accuracy                                70% ~ 100%  2 %

                                               0%  ~  69% unspecified

Actualization intervalabout     1 Sec.

Alarm Delay                            10 Sec.

Pulse Rate                               Measuring and Alarm Range 20~300 bpm

                                                Resolution       1bpm

                                                Accuracy ±3bpm

 

TEMP

 

Channel                                         2

Measuring and Alarm Range        0 ~ 50 ºC

Resolution                                     0.1 ºC

Accuracy                                       ±0.2 ºC

Actualization intervalabout            1 Sec.

Average Time Constant                 < 10 Sec.

 

IBP

 

Label                                           ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range       ART 0 ~ 300 mmHg

                                                   PA -6 ~ 120 mmHg

                                                   CVP/RAP/LAP/ICP-10 ~ 40 mmHg

                                                   P1 / P2-10 ~ 300 mmHg

Press Sensor                              Sensitivity 5  uV/V/mmHg

                                                    Impedance 300-3000Ω

Resolution                                   1 mmHg

Accuracy                                     ±2% or 1mmHg which is greater

Actualization interval                   about 1 secretary

 

Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
We provide different kinds of Defibrillator & Monitor. Some are shown in the following pictures. For more infomation, please refer to our webside: guangzhou-medical.en.made-in-china.com.
12.1 Inch Patient Monitor with Capnography
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More