• Low Price Veterinary Hospital Biochemical Analyzer Filter
  • Low Price Veterinary Hospital Biochemical Analyzer Filter
  • Low Price Veterinary Hospital Biochemical Analyzer Filter
  • Low Price Veterinary Hospital Biochemical Analyzer Filter
  • Low Price Veterinary Hospital Biochemical Analyzer Filter
  • Low Price Veterinary Hospital Biochemical Analyzer Filter

Low Price Veterinary Hospital Biochemical Analyzer Filter

Item: Biochemical Analyzer Filter
Power Supply: AC100V-240V,50-60Hz
Storage: >100000 Results
QC & Calibrate: Auto Test in Real Time
Sample Type: Anti-Coagulation Whole Blood, Serum, Plasma
Sample Volume: 100UL
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
MC-SMT-100V
Testing Time
12mini/Person
Testing Principle
Absorption Spectroscopy, Transmission Turbidimetry
G.W./N.W
5 Kg
Size
31cm(H)*21cm(W)*28(L)Cm
Transport Package
Export Standard Packaging for Air and Sea
Trademark
MeCan
Origin
China (Mainland) Guangdong
Production Capacity
5000

Product Description

low price veterinary hospital biochemical analyzer filter

Model: MC-SMT-100V
Low Price Veterinary Hospital Biochemical Analyzer Filter
 

Product Description

MCL-SMT-100V is a portable automatic chemistry analyzer which is applied to clinical biochemistry analysis with lithium heparin anticoagulant whole blood, serum and plasma. And MCL-SMT-100V covers various applications from emergency departments to clinical labs, from ICU to surgery centers, from anesthesia department to respiratory care, from home to ambulance.

In addition, the MCL-SMT-100V system consists of a 5-kg portable analyzer and pre-configured reagent, or "rotor", disks that enable veterinarians to obtain a clear, comprehensive picture of a patient's condition, and veterinarians needn't add reagents by themselves.

 

Advantages

 

Simple operation

Free of centrifugation, water treatment system and professional doctor. Anyone can operate only by 3 steps. Add 100ul whole blood into disc, put disc into analyzer and delay 12 minutes to print report.

 

Little sample volume

Sample volume is 10-20% of normal chemistry analyzer.

 

Accurate Result

Test sample and dilution volume measured by mould, without random error.

 

No carryover

Portable,5 Kg, 0.02m3

Provide with AC and DC power, suitable for use at movable place and outdoor.

 

Free maintenance

Auto QC and real time Calibrate.

Stroboscopic xenon lamp, service life is over one hundred million times.

No internal fluid flow, no pump and valve, decrease machine fault.

 

Specification

 

Sample type

Anti-coagulation whole blood, serum, plasma

Sample volume

100ul

Bar code

Two-dimensional bar code

Testing time

12mini/person

Testing principle

absorption spectroscopy, transmission turbidimetry

Testing method

end point, kinetic, fixed time, turbidmetry, etc.

Temperature

37 ±0.2 degrees celsius

Absorbance

0-4.5Abs

Resolution

0.001Abs

Carryover

0

QC & Calibrate

auto test in real time

Work environment

Temperature:10-32 degrees Celsius, Humidity: <90%

Optic system

Reversed optic. 340nm, 405nm, 450m, 505nm, 546nm, 578nm, 630nm, 850nm

Light source

12V/20W,.Tungsten halogen lamp's life span reaches over 2500hours

Power supply

AC100V-240V,50-60Hz

Power

70W

Interface

7.0 inch True color LCD touch screen, multi-language choice.

Vet version is optional

Storage

>100000 results

Printer

built-in thermal printer and external printer

Data port

4 USB, 1 RS232. Software upgrade function by WIFI

Weight

5KG

Size

31cm(H)*21cm(W)*28(L)cm

Animal types

Over10 species

 

Analyzer Uses

3 Steps operation of the dry chemistry analyzers:

 

Step 1: Add Sample

Simply collect 0.1cc of whole blood, serum or plasma, and transfer it to the self-contained reagent disc. The single use, disposable disc contains all the reagents and diluent necessary to perform a complete fixed multi-test panel.

 

Step 2: Insert Disc

Follow the touch screen commands. Place the disc into the analyzer drawer, enter requested information and the biochemistry analyzer does the rest. In approximately 12 minutes, results are ready.

 

Step 3: Read Results

Complete panel results including patient demographics, chemistry concentrations, reference ranges, sample integrity indices and iQC are available on the full color display, printed on a self-adhesive print out, transmitted to an external printer, The automatic biochemistry analyzer will store on-board up to 100000 patients and quality control results.


Low Price Veterinary Hospital Biochemical Analyzer Filter
Low Price Veterinary Hospital Biochemical Analyzer Filter
 

Product Description

The dry chemistry analyzer is an instrument that uses the serum of centrifuged blood sample, and induces reactions using reagents to measure various components, such as sugar, cholesterol, protein, enzyme, etc.

 

These tests are performed for routine health checks or at hospitals, and the results provide objective data enabling early detection and diagnosis of disease, as well as indicating the effects of treatment and patient prognosis.

 

The dry chemistry analyzers feature:

Portable small size, 5kg, 0.02 m3, suitable for use at movable place and outdoors,

Simple operation, free of centrifugation, water treatment system and professional doctor, anyone can operate only by 3 steps, Little sample volume, sample volume is 1/12 to 1/10 of traditional chemistry analyzer, Accurate result, test sample and dilution volume measured by mould, without random error, no carryover.

 

  veterinary hospital biochemical analyzer filter

Advantage

Freeze-drying reagent, disposable package, storage life as long as 1 year,

Internal autonomous channel design, disposable disc avoid carryover,

Multi reagent disc for choose.

 

The Types of Animal Biochemistry Reagent Disc

1.The 14 Comprehensive Diagnostic Parameters:

K+, Na, ALT, ALB, ALP, AMY, TBIL, GLU, GGT, CHE, CREA, TP, UA, UREA, GLOB*

2.The 13 Health Check Parameters

ALT,ALB, AST, AMY, CA, CREA, GLU, TBIL, CK,TG,UREA, PHOS, TP, GLOB*

3.The 10 Emergency and Severe Disease Parameters

K, Na, Cl,TCO2, ALT, AMY, GLU, UREA, CREA, CHE

4.The 9 Liver Function Parameters

ALT, AST, ALB, ALP, TBA, TBIL, GGT, TC, TP

5.The 8 Kidney Function Parameters

CA, PHOS, TCO2, ALB, GLU, UREA, CREA,UA

6.The 7 Electrolyte Parameters

K+, Na+, Cl, CA, TCO2, Mg, PHOS

7.The 9 Pre-operation Test Parameters

ALT, ALP, AST, GLU, UREA, CREA, TP, LDH, CK

8.The 11 Birds and crawlers

K+, Na+, CA, PHOS, ALB, AST, CK, TBA, GLU, TP, UA, GLOB*

9. The Others

It is workable to customize according to your request.


Low Price Veterinary Hospital Biochemical Analyzer Filter

Packaging & Shipping

 

The product was strong export package & suitable for deliver by air, express or sea.

1. Express: Ship it by UPS/ DHL/ FEDEX/ TXT express which is door to door. (3~5 days)

2. Air: Ship it by air cargo which you need go to airport to take it. (2~7 days)

3. Sea: If goods are large quantity and you are not in hurry, we can ship it by sea to save freigt cost. (About one month)
Low Price Veterinary Hospital Biochemical Analyzer Filter
 

FAQ

 

Q: What are the power requirements to operate SMT 100 analyzer?

A: The analyzer requires 100-240 volts AC, 50-60 Hz.

 

Q: What is the shelf life of the reagent discs?

A: The reagent discs can be stored for up to 12 months at 2-8°C.

 

Q: Can the expired reagent discs be used?

A: No, the result of the test will be unreliable.

 

Q: How long can the reagent disc be used after removing from the foil pouch?

A: After opening the pouch, the disc should be used within 20 minutes. Do not place the disc back into the refrigerator for later use.

 

Q: Can reagent discs be used again?

A: No, it can only be used once. It is a single-use disposable reagent disc. One disc one sample.

 

Q: What types of samples can be used with the SMT 100 analyzer?

A: The sample can be whole blood, plasma or serum.

 

Q: What is the sample volume required for a test?

A: 100ul is required to run a test. In case of rechecking, it is recommended that collecting blood sample is not less than 250ul.

 

Q: Before testing, does the reagent disc need to take out from refrigerator to guarantee the test temperature?

A: Yes, to avoid congealing and guarantee test temperature, before unpack and test, reagent disc

have to be placed 20 minutes after taking our from refrigerator or low temperature storage tank.

 

Q: In the process of sample and control test, when clicking STOP button, can the test disc be used as a new disc again?

A: The stopped test disc can't be used again. If it is not must situation, please don't stop it.

 

Q. Do the users need to add reagent?

A: No, the reagent is already packed well in each of the disc hole before packing foil pouch.

 

Q: How to maintain the instrument?

A: Keep the instruments shell and drawer clean. Compared to the traditional analyzer, our instrument has less maintenance. 
Low Price Veterinary Hospital Biochemical Analyzer Filter

ANALYZER COMPARISON

 

CHEMISTRY ANALYZERS COMPARISON

SEMI-AUTO

FULLY-AUTO

DRY CHEMISTRY

MCL-SMT-100 SERIES

SIZE AND WEIGHT

Small and Light

Big and Heavy

Small and Light

Small and Light

ADVANTAGES

Cheap and Small Size

Accurate for Quantity Samples Test

Cheap and Fast for Single Parameter Test

Fully Automatic No Carryover for Reagents Easy Use Small Fast and Accurate for One Sample Multiple Parameters Test

DISADVANTAGES

Too Complex in Operation and Carryover Pollution

Complex in Operation and Carryover Pollution Big Size

Few Parameters and  Not So Accurate  for Testing

Not Economic for Single Parameter Test

APPLICATIONS

Clinics Hospitals Labs

Hospitals

Clinics Hospitals Labs Emergency Animals POCT

Clinics Hospitals Labs Emergency Animals Army  Marine POCT

FULLY HEALTHY CHECK NEED BLOOD

2-5 cc

2-5 cc

0.1 cc

0.1 cc

 

 

Company Information

Our MeCan is high-tech enterprise of high quality and minded entrepreneurs, and integrates the R&D, manufacturing, sales and service about the IVD products.

 

The group, which owns advanced technology, excellent production, considerate sales and services, has been sparing their heats and soul to service each of our old and new clients from home and aboard.

 

In the spirit of surviving by brilliant quality, developing by sincerity and trust, with the excellent products, competitive price and perfect service, our MeCan is continuously and steadfastly attracting domestic and oversea clients, and building long-term stable friendly business development relationship.
Low Price Veterinary Hospital Biochemical Analyzer Filter
 

To satisfy you is our MeCan people long-lasting pursuit.

 

 biochemical analyzer filter

Our Certifications

MeCan has certificates including:   ISO13485:2012 Quality Management System issued by TUV CE Declaration of Conformity listed by TUV as IVD device Free Sale Certificate issued by China Council for the Promotion of International Trade China Chamber of International Commerce Patents (We are the only manufacturer of this kind of chemistry analyzer in China, we found some companies stolen our product pictures, MeCan will protect our right.)
Low Price Veterinary Hospital Biochemical Analyzer Filter
We offer all vet clinic equipment: vet table, vet cage, vet infusion pump, vet injection pump, vet surgical instrument, vet ECG, vet monitor, vet ultrasound,vet x-ray machine and accessory, vet laboratory analyzer, Pet Treadmill, vet mortuary equipment, etc.
Low Price Veterinary Hospital Biochemical Analyzer Filter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now