Water Distillation Units Water Softner Laboratory Filtration System

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Water Treatment
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (26)
Find Similar Products

Basic Info.

Model NO.
MC-PWT
Certification
ISO13485
Group
All
Water Distillation Units
Water Distilation Unit
Water Softner
Water Distillation Units
Laboratory Filtration System
Water Treatment
Recovery Rate
70-75%
Desalination Rate
99.8%
Bacterial Remove Rate
99.8%
Valves
SUS 304
Pipeline Used
Pretreatment Part-UPVC
2ND Stage RO&EDI Part
Pharmaceutical Grade SUS316
Voltage and Frequency
380V, 50Hz; 3-Phase, 4-Wire
Transport Package
Standard Packing for Export
Specification
CE
Trademark
MeCan
Origin
Guangzhou
HS Code
90189030
Production Capacity
1000 Per Month

Product Description

Water Distillation Units Water Softner Laboratory Filtration System
Model:MC-PWT


A. Water analysis:
Source water: need to be given by clients, usually tap water.
Treated water quality: pure water as per required.
B. Relative parameters:
Capacity: final outlet after 2 stage RO + EDI 500 L/H.
Recovery rate: 70-75%.
Desalination rate: 99.8%.
Bacterial remove rate: 99.8%.
Valves: SUS 304.
Pipeline Used:
Pretreatment part-UPVC.
1st stage RO-SUS304.
2nd stage RO&EDI part:Pharmaceutical grade SUS316.
Voltage and frequency: 380V, 50Hz; 3-Phase, 4-wire.
Power supply: 5 KW.
Application:
Medicine industrial producing, pharmaceutical producing, drops producing etc.
Dialysis/Hemodialysis/Injection in hospital use.
Control way:
Touch screen + PLC auto control.
Outlet water conductivity: ultra pure water. Stable quality.
C. Working Process:
D.General Description
This plant adopts pretreatment + 2 pass RO + EDI system tech to treat water
as per given and reach standards as per required.
Both Auto & Semi Auto are used and can be changed accordingly.
E. Detail introduction:

SUS Source Water Tank
With H, L level control. Regulate water supply to the pre-treatment, prevent the
effects of water insufficient, effective protect the work of booster pump.

SUS Booster Pump
Provide power for pretreatment & RO system.
For plant works for 12 hours or more per day, we advise 2 pumps, 1D+1S.
Improve efficiency and prolong working life.

SUS Manganese Sand + Quartz Sand Filter
Get rid of Iron, turbidity, SS matter, organic matter, colloid, etc. In the water.

SUS Active Carbon Filter
Remove color, free chloride, organic matter, harmful matter, etc. Remove 99%
of chlorine, organic chemicals. Provides enhanced reduction of taste, odor, and
color. Protect and prolong the life of RO membrane.

SUS Water Softener
Soft water and reduce water hardness. Make it suitable for final use.

SUS PP Filter
Prevent any deposition of large Particles, holding back any large particulates
such as iron, dust, SS matter, impurity into RO membrane.

SUS 1st Stage High Pressure Pump
Provide power for 1st stage RO system, equipped with over-heat, protect and
pressure controller. For plant works for 12 hours or more per day, we advise 2
pumps, 1D+1S. Improve efficiency and prolong working life.

1st Stage RO System
Adopts high desalination rate DOW / HYDRANAUTICS RO membrane.
Removes the following water contaminants: lead, cooper, barium, chromium,
mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium etc.
Clear water, green water !

PH adjust system
Adjust and control PH value of the water.

1st Stage RO Water Tank
Store 1st stage RO water, buffer for 2nd stage RO system. Material: SUS 304.

SUS 2nd Stage High Pressure Pump
Provide power for 2nd stage RO system, equipped with over-heat, protect and
pressure controller. For plant works for 12 hours or more per day, we advise 2
pumps, 1D+1S. Improve efficiency and prolong working life.

2nd Stage RO System
Adopts high desalination rate DOW / HYDRANAUTICS RO membrane.
Further purified water outlet from 1st stage RO system.

EDI booster pump
Provide power for EDI system.
For plant works for 12 hours or more per day, we advise 2 pumps, 1D+1S.
Improve efficiency and prolong working life.

SUS UV sterilization
Makes water live and further sterilization and disinfection.

SUS PP Filter
Prevent any tiny impurity enter into EDI system.

EDI system
Will make use of Siemens EDI 0.5T/H which has been in water treatment for
Long term, outlet stable water quality.
Note: the pure water tank is flexible in size according to user's requests.

Electrical Control System
Use Germany Famous brand Schneider control components. Auto control
system: WEINVIEW touch screen+Mitsubishi PLC.
Material: SUS, worlds will be printed on the panel.
F. Detail list: will be decided by clients detail requirements and situation.
I. Reference picture:


Water Distillation Units Water Softner Laboratory Filtration System
Water Distillation Units Water Softner Laboratory Filtration System
Water Distillation Units Water Softner Laboratory Filtration System
Water Distillation Units Water Softner Laboratory Filtration System
Water Distillation Units Water Softner Laboratory Filtration System
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More