Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
15 inch, 800x600 color TFT, multi-channel display, wave channel: up to 13 waves.
SpO2 features a DSP algorithm offering exceptional performance even during movement, and provides excellent performance in low perfusion conditions.
NIBP VET algorithm supports a range of animals from small cats to horses, and includes NIBP overpressure protection.
Unique and clear human voice alarm system.
Standard RJ45 network connection, with an optional USB WIFI module for seamless connectivity to CMS.
USB data output equipped with software for easy data viewing on computers.
Gas module automatically detects five anesthesia gas types: HAL, ENF, ISO, SEV, and DEV.
Versatile screen layout options, including a Big Font screen; parameters and waves can be toggled on and off for each accessory cabinet.
Technical Specifications
ECG | SPO2 |
Lead : 3/5 | SpO2,PR,PI |
5 lead mode: I, II, III, aVR, aVL, aVF, V | Accuracy: ±2%( 70~100%) |
3 ECG channels, 7 ECG waves in ECG full lead mode | Pulse Rate: 20~250bpm |
HR:15-500BPM | Temperature |
Gain : X1/4,X1/2,X1,X2 | Channel : 2 |
Wave speed : 12.5/25/50 mm/s | Measure and Alarm Range0 - 50°C |
Pacemaker | Sensor type : rectal |
Arrythmia analysis | Unit : °C |
ST analysis | Accuracy : ±0.1°C |
Filter mode: other, monitor, surgery | Recorder |
RESP | 3 channals |
Impedance between RA-LL or RA-LA | Storage |
RESP lead : I/II | ≥720 hours trend graph and trend table |
Wave speed : 6.25, 12.5, 25mm/s | 2 houss wave review |
Apnea Alarm,5~120s | 200 alarm review |
NIBP | Alarm |
Method : Oscillometry | 3 levels alarm |
For animal from <10kg to > 20kg | All the alarm limit can be adjusted by user. |
Unit : mmHg ,Kpa | Unique Voice alarm |
Mode: Manual,Auto,STAT | IBP |
Measure and Alarm Range | Sensor: OHMEDA or BD, EDWARD compatible |
SYS 40~280 mmHg | Channels: 2 |
DIA 10 ~220 mmHg | Measuer Range: -50~ 360 (mmHg) |
MEAN 20 ~ 240 mmHg | Accuracy(no sensor): ±2% or £1mmHg, use the greater |
Cuff 0 ~ 300mmHg | CO2 |
Static pressure: ±3mmHg | Measuer Range: 0%~13% |
Automatic measurement interval time: | Accuracy: ±2 mmHg @<5.0% COz (at ATPS) |
1 minute ~ 480 minutes | Breath Rate: 3- 150 bpm |
Standard:
ECG, NIBP, SpO2, PR, TEMP, RESP
Optional:
Mainstream/Sidestream EtCO2,
GAS, IBP-1/IBP-2, Thermal Recorder,
Wall Mount, Trolly, CMS