Customization: | Available |
---|---|
Product Name: | Half Body CPR Training Manikin |
Implement Standard: | 2010 Guideline for CPR |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Implement standard: 2010 guideline for CPR
Features
1. Simulate standard open airway
2. External breast compression, intensity display of corrects (at least 5cm):
1) Buzzing sound of correct compression intensity
2) Alarming sound of wrong compression intensity
3. Artificial respiration (inhalation): the volume of inhalation is observed through observing the wave of breast;
4. Operation methods: exercise operation
5. Power supply: battery
PACKAGE SIZE: 80*30*40cm
G.W.: 13KGS
Implement standard: 2010 guideline for CPR
Features
1. Simulate standard open airway
2. External breast compression, intensity display of correct (at least 5cm):
1) The yellow indicator light display of correct compression position
2) Buzzing sound of correct compression intensity, the green indicator light display
3) Alarming sound of wrong compression intensity, the red indicator light display
3. Artificial respiration (inhalation): the volume of inhalation is observed through observing the wave of breast;
4. Operation methods: exercise operation
5. Power supply: battery
PACKAGE SIZE: 80*30*40cm
G.W.: 13KGS
Implement standard: 2010 guideline for CPR
Features
1. Provide CPR operation practice;
2. Inflation: multiple ventilation ways, mouth to mouth, bag valve-mask to mouth, mechanical ventilation; the chest will rise when the ventilation is performed properly;
3. External chest compression: the manikin features important anatomical landmarks can effectively teach and practice external chest compression; it includes rib cage, jugular notch, sternum and xiphoid process;
4. Can simulate carotid pulse. The instructor can vary the intensity and rate of the carotid pulse by strength applied to the bulb;
5. Can practice the techniques of abdominal thrust, for the removal of airway foreign body obstruction;
Model: MCT-KE-180S
Implement standard: 2010 guideline for CPR
Features
1. Simulating standard open airway
2. External breast compression: display device and alarm device;
a) Indicator light display of correct and wrong compression; alarm of wrong compression;
b) Intensity display of correct (at least 5cm) and wrong (less than 5cm) compression; alarm of wrong compression.
3. Artificial respiration (inhalation): display device and alarm device;
a) Inhalation <500ml or > 600ml, wrong indicator light display and alarm prompting; Inhalation between 500-600ml right indicator light display;
b) Ratio of compression and artificial respiration: 30:2 (one or two person).
4. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration
5. Operation frequency: at least 100 times per minute
6. Operation methods: exercise operation
7. Examination of pupil response: mydriasis and myosis
8. Working conditions: Input power is 110-240V
PACKAGE SIZE: 80*30*40cm
G.W.: 13KGS
Implement standard: 2010 guideline for CPR
Features
1. Simulating standard open airway
2. External breast compression: display device and alarm device
a) indicator light display of correct and wrong compression ; alarm of wrong compression;
b) Intensity display of correct (at least 5cm) and wrong (less than 5cm) compression; alarm of wrong compression.
3. Artificial respiration (inhalation): display device and alarm device
a) Inhalation <500-600ml or > 600ml, wrong indicator light display and alarm prompting; inhalation between 500-600ml right indicator light display;
b) Indicator light display open airway;
c) Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting.
4. Ratio of compression and artificial respiration: 30:2 (one or two person).
5. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration.
6. Operation frequency: at least 100 times per minute
7. Operation methods: exercise operation
8. Examination of pupil response: mydriasis and myosis
9. Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse
10. Working conditions: Input power is 110-240V
Optional function
1. Endotracheal intubation
2. Gastrolavage
PACKAGE SIZE: 80*30*40cm
G.W.: 13KGS