Portable Defibrillator Monitor

Product Details
Customization: Available
Control: Touch-Screen
Parameters: ECG, Hr/Pr, NIBP, SpO2, Resp, Temp
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (26)
  • Portable Defibrillator Monitor
  • Portable Defibrillator Monitor
Find Similar Products

Basic Info.

Model NO.
MC-PMN3
Transport Package
Export Standard Packaging for Air and Sea
Trademark
Export standard packaging for air and sea
Origin
China (Mainland) Guangdong
Production Capacity
5000

Product Description

portable defibrillator monitor

 

Model: MC-PMN3

 

1.Touch-screen control;
2.8.4" high brightness and high resolution TFT-LCD display;
3.Water-proof and anti-hock, can be used in rainny and tough condition;
4.Li-ion rechargeable battery can support 8 hours'continuous working;
5.2 probe and battery bag, very easy to use and pack-up; 
6.Standard configuration: ECG, HR/PR, NIBP, SPO2, RESP, TEMP


Summary of features and benefits
 Innovative rainproof, anti-shake andanti-impact design proven reliability
and durability in conventional medicalsettings, as well as some far more
challenging environments,such as "highhumidity", "high-risked transport"...
Extensive quality controls, such as "droptesting," ensure that Zondan products
continue to set the industry standard forboth reliability and durability.

 

Standard features you need, includingtouch screen, 3/5 lead ECG, NIBP, SpO2,

Temperature, ST segment analysis

 

Up to 8 hours run time on two Li-ion batteries

Flexible mounting solutions makes it easyto use in different environment

From the scene of the accident andcritical-care situations where seconds
count, the Apollo N3 boots up within10 second. The excellent-performanced
device save much more time for the patient

 

PERFORMANCE SPECIFICATIONS
Display

Type and size 8.4" Color TFT Touch Screen
Resolution 800×600


Electrical
AC input voltage 100-240V
AC input frequency 50/60Hz
AC input power <70VA
Battery
Type Internal Li-ion battery
Voltage 12V
Maximum number of batteries 2
Battery life 8 continuous using after fully charged
Patient Range Neonate, pediatric, and adult patients


ECG
Lead type 5-Lead selectable
5 leadwire I,II,III,V,AVR,AVL,AVF
Gain ×0.25,×0.5,×1,×2,Auto
Sweep speed 12.5mm/s, 25mm/s, 50mm/s
Standardizing voltage 1mV marker
Bandwidth(Surgery mode) 1-20Hz
Bandwidth(Monitoring mode) 0.5-40Hz
Bandwidth(Diagnostic mode) 0.05-130Hz
Multi-lead display 6 waveforms
ECG derived HR


Heart Rate for Adult 15-300BPM
Heart Rate for Neonate/Pediatric 15-350BPM
Heart Rate Accuracy ±1BPM or ±1%, whichever is greater
Heart Rate Resulotion 1BPM
ST Segment
ST segment range -2.0mv to 2.0mv
ST alarm range -2.0mv to 2.0mv
ST segment accuracy -0.8mv to 0.8mv


ST segment error ±0.02mv
Arrythmia type 13 types
ST analysis 2-lead measurement
Pace
Pace detection Yes
Pace rejection amplitude ±2 mV ~ ±700mV
Pace rejection width 0.1ms ~ 2ms
Pace rejection rise time 10μs~100μs
Over/under shoot
Baseline drift <0.5mv per hour with a±700mv,2ms


Pacemaker pulse
Temperature
Scale ºCelsius(C) or ºFahrenheit(F)
Probe type YSI typs
Parameters T1,T2 and TD
TD(Temperature difference) Yes
Measurement range 0~50ºC
Resolution 0.1ºC
Accuracy ±0.1ºC
Refreshing time approximately 1S


Pulse oximetry
SpO2 measurement range 35%~100%
PPR measurement range 20bpm~300bpm
Resolution 1%
Error ±3bpm
Accuracy ±2%(70%-100%); unspecified(0-69%)


NIBP
Measurement technique Oscillometric
Displayed parameters Systolic, diastolic and mean
Measurement mode Manual, Auto,STAT
Auto cycle time 0-4 Hours
Measurement unit mmHg/kPa selectable
Range of Systolic pressure Adult: 40-270mmHg
Pediatric:40-200mmHg
Neonate:40-135mmHg
Range of mean pressure Adult: 20-235mmHg
Pediatric:20-165mmH
Neonate:20-110mmHg
Range of diastolic pressure Adult: 10-215mmHg
Pediatric:10-150mmHg
Neonate:10-100mmHg
Accuracy 5%
Resolution 1mmHg
Over-pressure protection Double safety protection


Respiration
Measurement technique Impedance variation detection
Range Adult:7~120rpm
Pediatric/Neonate: 7~150rpm
Apnea alarm Yes, 10s,15s,20s,25s,30s,35s,40s
Sweep speed 6.25mm/s, 12.5mm/s, 25mm/s
Gain 0.25, 0.5, 1, 2, 4


Recorder
Type Thermal dot array
Number of waveform channels 3
Paper width 112mm
Portable Defibrillator Monitor
Portable Defibrillator Monitor
Portable Defibrillator Monitor
Please Send inquiry to us for the portable defibrillator monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More