15-inch, 800x600 color TFT display, featuring multi-channel display capabilities with up to 13 wave channels.
Advanced SpO2 functionality with DSP algorithm for remarkable performance during movement. Featuring PI, it ensures superior performance even in low perfusion scenarios.
NIBP VET algorithm supports a diverse range of animals from small cats to large horses, ensuring overpressure protection.
Unique human voice alarm system for enhanced monitoring.
Standard RJ45 network connectivity with an optional USB WIFI module for seamless integration with CMS.
USB data output allowing comprehensive data review and analysis on a computer.
Gas module intelligently auto-detects five types of anesthesia gases: HAL, ENF, ISO, SEV, and DEV.
Multiple screen layouts including a Big Font screen. Parameters and waveforms can be toggled on and off for each accessory cabinet.
Technical Specifications
ECG | SPO2 |
Lead : 3/5 | SpO2,PR,PI |
5 lead mode: I, II, III, aVR, aVL, aVF, V | Accuracy: ±2%( 70~100%) |
3 ECG channels, 7 ECG waves in ECG full lead mode | Pulse Rate: 20~250bpm |
HR:15-500BPM | Temperature |
Gain : X1/4,X1/2,X1,X2 | Channel : 2 |
Wave speed : 12.5/25/50 mm/s | Measure and Alarm Range0 - 50°C |
Pacemaker | Sensor type : rectal |
Arrythmia analysis | Unit : °C |
ST analysis | Accuracy : ±0.1°C |
Filter mode: other, monitor, surgery | Recorder |
RESP | 3 channals |
Impedance between RA-LL or RA-LA | Storage |
RESP lead : I/II | ≥720 hours trend graph and trend table |
Wave speed : 6.25, 12.5, 25mm/s | 2 houss wave review |
Apnea Alarm,5~120s | 200 alarm review |
NIBP | Alarm |
Method : Oscillometry | 3 levels alarm |
For animal from <10kg to > 20kg | All the alarm limit can be adjusted by user. |
Unit : mmHg ,Kpa | Unique Voice alarm |
Mode: Manual,Auto,STAT | IBP |
Measure and Alarm Range | Sensor: OHMEDA or BD, EDWARD compatible |
SYS 40~280 mmHg | Channels: 2 |
DIA 10 ~220 mmHg | Measuer Range: -50~ 360 (mmHg) |
MEAN 20 ~ 240 mmHg | Accuracy(no sensor): ±2% or £1mmHg, use the greater |
Cuff 0 ~ 300mmHg | CO2 |
Static pressure: ±3mmHg | Measuer Range: 0%~13% |
Automatic measurement interval time: | Accuracy: ±2 mmHg @<5.0% COz (at ATPS) |
1 minute ~ 480 minutes | Breath Rate: 3- 150 bpm |
Standard Parameters:
ECG, NIBP, SpO2, PR, TEMP, RESP
Optional Modules:
Mainstream/Sidestream EtCO2,
GAS, IBP-1/IBP-2, Thermal Recorder,
Wall Mount, Trolley, CMS