Full-Auto Glycated Hemoglobin Hba1c Analyzer

Type: Biochemistry Analyzer
Certification: CE, FDA, EEC, MSDS, ISO13485
Product Type: Glycated Hemoglobin Hba1c Analyzer
Testing Method: Low Pressure Ion Exchange Liquid Chromatography
Testing Item: Glycated Hemoglobin Hba1c
Testing Scope: 3%-18%
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
MCL-GH01
Testing Parameters
Precision(CV)≤3%, Accuracy(V) ≤1.50%
Testing Time
4 Minutes(Reporting)
Sample Type
Venous Blood(EDTA Anticoagulation), Peripheral Fin
Transport Package
Standard Packing for Export
Specification
CE FDA
Trademark
MeCan
Origin
Guangzhou China
Production Capacity
3000 Per Month

Product Description

Full-auto Glycated Hemoglobin HbA1c Analyzer

Model: MCL-GH01
Accurate Principle of Methodology
Adopts classical and accurate principle of methodology - Ion exchange liquid chromatography, It is the gold standard of HbA1C analysis, and it is the only analysis method to really separate HbA1C directly by measuring the piecemeal absorbance through continuous test on line,? and obtain the correct area percentage with integration.


Accurate separation 4-gradient elution
The novel 4-gradient elution for HbA1C can separate accurately glycated hemoglobin with 4-gradient elution of corresponding concentration reagent aiming at HbA1C instead of routine ?elution process produced by high and low concentration mixture.

High Separation Liquid Chromatographic Column
High separation liquid chromatographic column made of imported resin with volume of Φ 9mm x 45mm and weight of 2.5g which is 15 - 20 times greater than general micro chromatographic column. High efficiency chromatographic column for 300 tests ensure the accuracy of test results.

High Sensitivity 415nm LED Integral Photometer
High sensitivity 415nm LED integral photometer has the characteristics of correct wavelength, stable light source, full aluminum alloy structure, high anti-interference performance, multi-lens focusing, micro cuvettes and high sensitivity. It can record accurately analysis curve.

Supply with Original Calibrator
The international standard value tracing is adopted. The authoritative reference material for quality control is used to transfer the numeric value. Each set of reagent is supplied with two sets of calibrator for proper calibration so as to ensure that the test results are correct and reliable and thoroughly to avoid individual error caused by factor calibration.


Precision Chromatographic Column and Thermostatic Apparatus
Precision chromatographic column and reagent thermostatic control apparatus ensure that Chromatographic column and reagent are not affected by environment temperature and effectively guarantees the repeatability and correctness of the test results

Specification:
Testing Method Low pressure ion exchange liquid chromatography
Testing Item Glycated hemoglobin HbA1c
Testing Scope 3%-18%
Testing Parameters Precision(CV)≤3%, Accuracy(V) ≤1.50%
Testing Time 4 minutes(reporting), Full-processing 6 minutes(including cleaning column and recovery time)
Sample Type Venous blood(EDTA anticoagulation), Peripheral finger blood
Sample Volume    5ul Whole blood for each sample
Functional Parameters
Photometer 415nm LED Integral flow colorimeter
Sampling mode Fully-auto 20 position sample turntable
Testing mode Auto test for batch, single test for emergency
Calibration Optional selection of 2 points or 4 points calibration, optional selection of manual or automation, Equipped with 2 groups of high and low level calibrators
Thermostatic control Column and reagent thermostatic control: 25 ±0.5ºC
Reagent matching One piece of column and reagent consumable/300 pieces of testing samples
Reagent allocation Each standard package inclues A, B, C, D eluent, calibrator, hemolytic agent, pump tubing
Output Parameters
Display 320×240 LC Graphic display, displaying real-time testing curve
Printer 58nm Thermal printer, printing testing curve and report
Report Output IFCC concentration value, NGSP area percentage, ADAG average glucose
Data storage 1000test report(including testing curve)
Communication interface RS232 communication interface, connecting to HIS/LIS system
Working Parameters
Power Supply AC220V±22V, 50HZ, 65VA
Size 408*390*230mm
Weight 8KG
Working Environment Temperature 12-30ºC, Relative humidity ≤85%
             
Medical Euiqpment
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Hospital Furniture and Surgical Equipment
Full-Auto Glycated Hemoglobin Hba1c Analyzer
X-Ray Machine and Ultrasound Scanner
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Obstetric Gynaecology Centre and Rehabilitation Therapeutic Apparatus
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Dental Clinic Equipment and Ophthalmoscope
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Laboratory Equipment
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Sterilizer & Disinfection Products
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Mortuary Equipment
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Homecare Product
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Veterinary Equipment and Education Equipment
Full-Auto Glycated Hemoglobin Hba1c Analyzer
Why Choose MeCan





Full-Auto Glycated Hemoglobin Hba1c Analyzer





































Reagent Standard Package Including QC, Calibrator, column, 400tests reagent

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now